Impacts of the use of long-term reversible contraceptive devices on women's health

Authors

DOI:

https://doi.org/10.33448/rsd-v10i15.23281

Keywords:

Contraceptives; Health risk; Intrauterine; IUD; Implan.

Abstract

The goal of this study was to carry out a systematic prism review using the prism technique that allowed us to identify the main health problems caused in women who used long-term reversible contraceptive devices. In the adopted methodology, the articles were selected through a process of 04 hierarchical levels, using cutoff criteria. At the first level, 1391 articles published between 2017 and 2021 were selected, in the SciELO, Academic Google, PubMed/MEDLINE and Virtual Health Library (Biblioteca Virtual de Saúde-BVS)/LILACS databases, using keywords as criteria. At the following levels, articles that contained themes, titles and abstracts related to the work were selected. After selection and screening, there was a reduction in the number of articles to 50 selected, representing 3.59% of the total, with PubMed/MEDLINE with 40 articles being the platform with the highest participation, corresponding to 2.88%. The other platforms presented the following values: SciELO 02 articles (0.14%); Academic Google and LILACS 04 articles each (0.28%). The main health problems and incidences in the platforms were also identified: bleeding (PubMed/MEDLINE 20%; LILACS and Google academic 4%); weight gain (PubMed/MEDLINE 16%; BVS/LILACS 4%); subdermal implant migration (PubMed 28%); influence on sexual function (PubMed/MEDLINE 6%); others (PubMed/MEDLINE 28%; BVS/LILACS 14%). It was found that the main health problems reported were bleeding and implant migration. Therefore, this reviews the main types of health problems caused by reversible contraceptive devices of long duration, in a short period of time, without compromising the accuracy of the results.

Author Biographies

Elizabeth Carvalho da Silva , Universidade Nilton Lins

Elizabeth Carvalho da Silva 
Graduate Student in Pharmacy
Department of Pharmacy/ Nilton Lins University 

Ronaldo da Silva Ferreira , Universidade de Aveiro

Department of Electronics, Telecommunications and Informatics - DETI
Doutoramento Student Aveiro - Portugal
Master of Electrical Engineering / Universidade Federal do Amazonas

Lucilene Ferreira Mouzinho , Instituto Federal do Maranhão

Lucilene Ferreira Mouzinho, PhD
Deparatamento de Engenharia Eletrotecnica

Instituto Federal do Maranhão

Vítor Hugo Paixão Ferreira, Universidade de Aveiro

Vítor Hugo Paixão Ferreira
MSc Engenharia Física/Universidade de Aveiro 
Pesquisador no Instituto de Telecomunicações  

References

Adeyemi-Fowode, O. A. A., & Bercaw-Pratt, J. L. (2019). Intrauterine devices: effective contraception with noncontraceptive benefits for adolescents. Journal of pediatric and adolescent gynecology, 32(5), S2-S6. DOI: 10.1016/j.jpag.2019.07.001

Albuquerque, J. S. (2018). Métodos anticoncepcionais reversíveis: uma revisão (Trabalho de Conclusão de Curso). Universidade de Campina Grande, 50.

Bahamondes, L & Monteiro, I. (2017). Comments on manuscript: vaginal misoprostol prior to intrauterine device insertion in women delivered only by elective cesarean section: a randomized double-blind clinical trial. Contraception, 95(4), 434-435. DOI: 10.1016 / j.contraception.2017.01.012

Bassis, C. M., Allsworth, J.E.,Wahl, H.N., Sack, D.E., Young, V.B. & Bell, J.D. (2017). Effects of intrauterine contraception on the vaginal microbiota. Contraception, 96(3), 189-195. DOI: 10.1016 / j.contraception.2017.05.017

Bearak, J., Popinchalk, A., Alkema, L., & Sedgh, G. (2018). Global, regional, and subregional trends in unintended pregnancy and its outcomes from 1990 to 2014: estimates from a Bayesian hierarchical model. The Lancet Global Health, 6(4), e380-e389. DOI: 10.1016/S2214-109X(18)30029-9

Boisen, A.B., Ostenfeldt, E.B., Erikstrup, L.T., & Bay, B. (2017). Genital actinomycosis and pelvic abscesses in a woman with a 13-year-old intrauterine device. UgeskrLaeger, 179(13).

Brandão, E. R. (2019). Métodos contraceptivos reversíveis de longa duração no Sistema Único de Saúde: o debate sobre a (in) disciplina da mulher. Ciência e Saúde Coletiva, 24(3). https://doi.org/10.1590/1413-81232018243.10932017

Carvalho, N.M., Chou, V., Modesto, W., Margatho, D., Garcia, E.A.L. & Bahamondes, L. (2017). Relationship between user satisfaction with the levonorgestrel-releasing intrauterine system and bleeding pattern. The Journal of Obstetrics and Gyneacology Research, 43(11), 1732-1737. DOI: 10.1111 / jog.13441

Clancy, A.A., Gerritze, R. & Pascali, D. Intrauterine device visualized as extrinsic bladder mass on citoscopy. (2017). International Urogynecology Journal, 28(9), 1429-1430. DOI: 10.1007/s00192-017-3382-8

Chai, W., Zhang, W., Jia, G., Cui, M. & Cui, L. (2017). Vesical transmigration of an intrauterine contraceptive device: A rare case report and literature review. Medicine (Baltimore), 96(40), 8236. DOI: 10.1097 / MD.0000000000008236

Cim, N., Soysal, S., Sayan, S., Yildizhan, B., Karaman, E., Cetin, O., Tolunay, H.E. & Yildizhan, R. (2017). Two Years Follow-Up of Patients with Abnormal Uterine Bleeding after Insertion of the Levonorgestrel-Releasing Intrauterine System. Gynecologic and Obstetric Investigation, 83(6), 569-575. DOI: 10.1159 / 000480012

Couto, M. C., Saiani, C. C., & Kuwahara, M. Y. (2020). Contracepção e Autonomia das Mulheres na Decisão pela Gravidez: Efeitos do Programa Bolsa Família. Anais do 48º Encontro Nacional de Economia. https://brsa.org.br/wp-content/uploads/wpcf7-submissions/1886/ENABER-2020-PBF-e-NNMC-com-identifica%C3%A7%C3%A3o-Copia.pdf

Colwill, A.C., Schreiber, C.A., Sammel, M.D. & Sonalkar, S. (2017). Six-week retention after post-placental copper intrauterine device placement. Contraception, 97(3):215-218. DOI: 10.1016 / j.contraception.2017.10.012

Cortessis, V.K., Barrett, M., Wade, N.B., Enebish, T., Perrigo, J.L., Tobin, J., Zhong, C., Zink, J., Isiaka, V., Muderspach, L.I., Natavio, M. & McKean-Cowdin, R. (2017). Intrauterine Device Use and Cervical Cancer Risk: A Systematic Review and Meta-analysis. Obstetrics Gynecolology, 130(6), 1226-1236 DOI: 10.1097 / AOG.0000000000002307

Darney, P.D., Stuart, G.S., Thomas, M.A., Cwiak, C., Olariu, A. & Creinin, M.D. (2017). Amenorrhea rates and predictors during 1 year of levonorgestrel 52 mg intrauterine system use. Contraception, 97(3):210-214. DOI: 10.1016 / j.contraception.2017.10.005

Dinehart E., Lathi, E.B. & Aghajanova, L. (2020). Levonorgestrel IUD: is there a long-lasting effect on return to fertility? Journal of Assisted Reproduction and Genetics. 37: 45–52. DOI: 10.1007/s10815-019-01624-5

Donders, G.G.G., Bellen, G., Ruban, K.. & Bulck, B. V. (2018). Short-and long-term influence of the levonorgestrel-releasing intrauterine system (Mirena) on vaginal microbiota and Candida. Journal of Medical Microbiology. 67(3), 308-313. DOI: 10.1099 / jmm.0.000657

Enfermagem Florence. (2020). Métodos Contraceptivos: Tipos e Eficácia. https://enfermagemflorence.com.br/metodos-contraceptivos-tipos-e-eficacia/adesivo-cutaneo/.

Fleith, D. D. S., Gomes, C. M. A., Araújo, C. M.M. & Almeida, L. S. (2020). Expectativas de Sucesso Profissional de Ingressantes na Educação Superior: Estudo Comparativo. Avaliação Psicológica, 19(3), 223-231. http://dx.doi.org/10.15689/ap.2020.1903.17412.01

Fierro-Calpa, L. R. (2021). Cuidados de enfermería en la mujer adulta. Boletín Informativo CEI, 8(1), 94-98.

Fontenelle, L. (2021). Gravidez com DIU? Entenda por que foto de bebê com dispositivo na mão não deve abalar eficácia do método. https://www.oitomeia.com.br/noticias/saude/2021/07/08/gravidez-com-diu-entenda-por-que-foto-de-bebe-com-dispositivo-na-mao-nao-deve-abalar-eficacia-do-metodo/.

Grandi, G; Farulla, A; Sileo, F. G & Facchinetti, F. (2018). Levonorgestrel-releasing Intra-uterine System as Female Contraceptives. Expert Opin Pharmacother. (19)7, 677-686. DOI: 10.1080/14656566.2018.1462337

Giordano, M.V., Giordano, L.A. & Panisset, K. S. (2015). Dispositivo intrauterino de cobre. FEMINA, 43(1). http://files.bvs.br/upload/S/0100-7254/2015/v43nsuppl1/a4850.pdf

Hofmeyr G. J., Singata M. & Lawrie, T. (2010). Copper containing intra-uterine devices versus depot progestogens for contraception. Cochrane Database of Systematic Reviews, (6), 1-23.DOI: 10.1002/14651858.CD007043.pub2.

Huss, A., Schaap, K. & Kromhout, H. (2017). A survey on abnormal uterine bleeding among radiographers with frequente MRI exposure using intrauterine contraceptive devices. Magnetic Resonance in Medicine, 79(2), 1083-1089. DOI: 10.1002/mrm.26707

Inal, Z.O., Inal, H.A. & Gorkem, U. (2017). Experience of Tubo-Ovarian Abcess: A Retrospective Analysis of 318 Patients in a Single Tertiary Center in Middle Turkey. Surgical Infections (Larchmt), 19(1), 54-60. DOI: 10.1089/sur.2017.215

Jatlaoui, T. C., Riley, H. E., & Curtis, K. M. (2017). The safety of intrauterine devices among young women: a systematic review. Contraception, 95(1), 17-39. DOI: 10.1016/j.contraception.2016.10.006

Junges, A. P. P., Andrade, A. M. D., Silva, J. M., Brandão, M. G., De Jorge, V., Maroso, G. S., & Lubianca, J. N. (2021). Métodos contraceptivos reversíveis de longa ação. (2021). Promoção e proteção da saúde da mulher ATM 2023/2, 13-26. https://lume.ufrgs.br/bitstream/handle/10183/223064/001127622.pdf?sequence=1&isAllowed=y

Lullo, J.J., Ethington, E., Arshanapalli, A., Reserva, J., Jiang, A., Adams, W., Graziano, S. & Tung, R. (2017). Incidence of androgenic dermatological side effects following placement of a levonorgestrel intrauterine device of menorrhagia: A survey-based study. Journal of American Academy of Dermatology, 79(2), 364-365. DOI: 10.1016 / j.jaad.2017.12.051

Luz, A. L. R., Barros, L. D. S. R., & Branco, A. C. D. S. C. (2021). Métodos contraceptivos: Principais riscos e efeitos adversos. Revista de Casos e Consultoria, 12(1), e24112-e24112.

Fontenelle, L. (2021). Gravidez com DIU? Entenda por que foto de bebê com dispositivo na mão não deve abalar eficária do método. https://www.oitomeia.com.br/noticias/saude/2021/07/08/gravidez-com-diu-entenda-por-que-foto-de-bebe-com-dispositivo-na-mao-nao-deve-abalar-eficacia-do-metodo/.

Machado, R. B. (2017). Uso de dispositivos intrauterinos (DIU) em nulíparas - São Paulo: Federação Brasileira das Associações de Ginecologia e Obstetrícia (FEBRASGO)

Malmborg, A., Brynhildsen, J., & Hammar, M. (2019). A survey of young women’s perceptions of the influence of the Levonorgestrel-Intrauterine System or copper-intrauterine device on sexual desire. Sexual & Reproductive Healthcare, 21, 75-80.

Madliki, M.S., Hofmeyr, G.J., d’Hellencourt, F.C.L. & Lawrie, T.A. (2017). Phychological, behavioural and physiological effects of three long-acting reversible contraception (LARC) methods: protocol for an ancillary study of the ECHO randomised trial. Britisg Medical Journal Open (BMJ), 7(11):e019205. DOI: 10.1136 / bmjopen-2017-019205

Mendes, L. V. (2021). Satisfação com o uso do implante contraceptivo e do dispositivo intrauterino com cobre entre usuárias de um hospital público da cidade de São Paulo [Dissertação de Doutorado]. Universidade de São Paulo.

Milletler, B. (2020). The world’s women 2020: Trends and statistics. Erişimadresi: https://worldswomen-2020-data-undesa. hub. arcgis. com/pages/violence-against-women-and-the-girl-child.

Mørch, L.S., Skovlund, C.W., Hannaford, P.C., Iversen, L., Fielding, S. & Lidegaard, Ø. (2017). Contemporary Hormonal Contraception and the Risk of Breast Cancer. The New England Journal of Medicine, 377(23), 2228-2239. DOI: 10.1056/NEJMoa1700732

Nakashira, E.S., Maximiano, L.F., Lima, F.R. & Ussami, E.Y. (2017). Abdominal and pelvic actinomycosis due to longstanding intrauterine device: a slow and devasting infection. Autopsy & Case Report, 7(1):43-47. DOI: 10.4322 / acr.2017.001

O’Brien, P.A. & Pillai, S. (2017). Uterine Perforation by intrauterine devices: a 16-year review. The Journal of Family Planning and Reproductive Health Care, 43(4):289-295. DOI: 10.1136 / jfprhc-2016-101684

Parlakgumus, A., Parlakgumus, H.A. & Ezer, A. (2017). A Rare Case of Acute Appendicitis: Migration of an Intrauterine Device. Journal of the College of Physicians Surgeons—Parkistan: JCPSP, 27(5), 323-324. DOI: 10.1002 / ccr3.4283

Paul, J., & Criado, A. R. (2020). The art of writing literature review: What do we know and what do we need to know? International Business Review, 29(4),

https://doi.org/10.1016/j.ibusrev.2020.101717

Rodrigues, E. W., Jr., Rodrigues, A. C., Silva, I. A. R., & Ferreira, G. M. (2021). A INSERÇÃO DA MULHER NO MERCADO DE TRABALHO NA ÁREA DA TECNOLOGIA. Revista Eletrônica da Faculdade Invest de Ciências e Tecnologia, 3(1). http://revista.institutoinvest.edu.br/index.php/revistainvest/article/view/32/25

Rose, S.B., Garrett, S.M., Stanley, J. & Pullon, S.R.H. (2017). Chlamydia testing and diagnosis following initiation of long-acting reversible contraception: A retrospective cohort study. Australian and New Zealand Journal of Obstetrics and Gyneacology, 57(6), 665-675. DOI: 10.1111 / ajo.12685

Sanders, J. N., Turok, D. K., Gawron, L. M., Law, A., Wen, L., & Lynen, R. (2017). Two-year continuation of intrauterine devices and contraceptive implants in a mixed-payer setting: a retrospective review. American journal of obstetrics and gynecology, 216(6), 590-e1. https://doi.org/10.1016/j.ajog.2017.02.003

Sano, M.., Nemoto, K., Miura, T. & Suzuki, Y. (2017). Endoscopic Treatment of Intrauterine Device Migration into the Bladder with Stone Formation. The Journal of Endourology Case Report, 3(1):105-107. DOI: 10.1089 / cren.2017.0038

Santos, L. J. M. L. (2020). Mulheres no mercado de trabalho: um estudo com mulheres em cargos de liderança (Trabalho de Conclusão de Curso). Centro Universitário Fametro, 29.

http://repositorio.unifametro.edu.br/jspui/bitstream/123456789/532/1/LIZ%20JORDELLE%20MOURA%20LIMA%20DOS%20SANTOS_TCC.pdf

Santos, O., Rigo, G.V., Macedo, A.J. & Tasca, T. (2017). Trichonomas vaginalis clinical isolates: cytodherence and adherence to polystyrene, intrauterine device, and vaginal ring. Parasitology Research, 116(12), 3275-3284. DOI: 10.1007 / s00436-017-5638-0

Sharma, A., Andankar, M. & Pathak, H. (2017). Intravesical Migration of an intrauterine Contraceptive Device with Secondary Calculus Formation. Korean Journal of Family Medicine, 38(3):163-165. DOI: 10.4082 / kjfm.2017.38.3.163

Silva, C. L. A., Angelo, L. K. G., Bernadino, A. C., Silva, C. A. A., Candido, S. A., Pacheco, A. L. D., Melo, I. S. & Castro, O. W. (2021). Importância da escola no conhecimento empírico sobre infecções sexualmente transmissíveis e métodos contraceptivos: promoção da saúde, na rede pública de ensino. Brazilian Journal of Development. 7(2), 20421-20432. DOI:10.34117/bjdv7n2-606

Silva, S.B., Ferreira, T.L.R.L., Fernandes, C., Nogueira, D., Barros, E.J., Mota, R., Oliveira, V.C.C. & Mendonça, B. (2014). Conhecimentos sobre métodos contraceptivos de acadêmicos de enfermagem da faculdade Montes Belos, em São Luís de Montes Belos-GO. Revista Faculdade Montes Belos (FMB), 8(4), 143-202.

Silva, W.S.L., Kodithuwakku, K.A.S.U.A., Aponsu, G.U.E., Rathnayake, R.M.M. & Rajasegaram, E. (2017). A large bladder stone caused by the intravesical migration of an intrauterine contraceptive device: a case report. Jornal of Medical Case Report, 11(1):293. DOI: 10.1186 / s13256-017-1461-6

Slywitch, N. C., Alves, B. P., de Paula Martins, E. A., Romão, J. V., Amorim, M. S., Vilela, M. P. D. & Novais, D. F. F. (2021). Comparação entre os dispositivos intrauterinos de cobre e hormonal: uma revisão narrativa. Revista Eletrônica Acervo Saúde, 13(5), e7345-e7345.

Simon, D.A., Smith, A.L. & Holzhauer, J.R. (2017). Case Report of an Ectopic Molar Pregnancy in the Presence of an Intrauterine Device. WMJ: official publication of the State of the State Medical Society of Wisconsin, 116(4): 215-217.

Ti, A. J., Roe, A. H., Whitehouse, K. C., Smith, R. A., Gaffield, M. E., & Curtis, K. M. (2020). Effectiveness and safety of extending intrauterine device duration: a systematic review. American journal of obstetrics and gynecology, 223(1), 24-35. DOI: 10.1016/j.ajog.2020.01.014.

Toumi, O., Ammar, H., Ghdira, A., Chhaidar, A., Trimech, W., Gupta, R., Salem, R., Saad, J., Korbi, I., Nasr, M., Noomen, F., Golli, M. & Zouari, K. (2017). Pelvic abcess complicating sigmoid colon perforation by migrating intrauterine device: A case report and review of the literature. International Journal of Surgery Case Report, 42:60-63. DOI: 10.1016 / j.ijscr.2017.10.038

Trindade, R. E. D., Siqueira, B. B., Paula, T. F. D., & Mendes, M. S. F. (2021). Uso de contracepção e desigualdades do planejamento reprodutivo das mulheres brasileiras. Ciência & Saúde Coletiva, 26, 3493-3504. https://doi.org/10.1590/1413-81232021269.2.24332019

Uçar, M.G., Şanl׀kan, F., Ilhan, T.T., Göçmen, A. & Çelik, C. (2017). Management of intra-abdominally translocated contraceptive devices, is surgery the only way to treat this problem?. Journal of Obstetric Gynaecology, 37(4):480-486. DOI: 10.1080 / 01443615.2016.1268577

Vasconcellos, E. D. C. C. & Brisolla, S. N. (2016). Presença feminina no estudo e no trabalho da ciência na Unicamp. Cadernos Pagu, 32:215-265.

Visentini, A. P. (2021). Mulheres em transição de carreira: significados para a saída de carreiras corporativas. (Dissertação de Mestrado). Universidade Federal do Rio Grande do Sul, 139.

Zhao, X., Liu, Q., Sun, H., Hu, Y. & Wang, Z. (2017). Chronic Systemic Toxicity Study of Copper Intrauterine Devices in Female Wistar Rats. Medical Science Monitor, 23:3961-3970. DOI: 10.12659 / msm.902137

Published

01/12/2021

How to Cite

SILVA , E. C. da .; FERREIRA , R. da S. .; MOUZINHO , L. F. .; FERREIRA, V. H. P. .; FIGUEIREDO, E. F. G. . Impacts of the use of long-term reversible contraceptive devices on women’s health. Research, Society and Development, [S. l.], v. 10, n. 15, p. e466101523281, 2021. DOI: 10.33448/rsd-v10i15.23281. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/23281. Acesso em: 12 nov. 2024.

Issue

Section

Health Sciences