Physical-chemical and microbiological analysis of water reservoirs for industrial supply

Authors

DOI:

https://doi.org/10.33448/rsd-v9i4.2795

Keywords:

Coliforms; Quality; Turbidity.

Abstract

The present work aimed to analyze the water quality of different reservoirs used to supply a small food industry located in the city of Campina Grande-PB, through the physical-chemical and microbiological parameters. The samples were collected in five different reservoirs and the following parameters were analyzed: pH, total dissolved solids, chlorides, residual chlorine, turbidity, total hardness. Microbiological analyzes were determined using the Colilert method. No high pH value was found, which would negatively affect the disinfection process, as it would accelerate the dissociation of hypochlorous acid. No residual chlorine concentration greater than 2.0 mg / L was observed in any sample. Therefore, the registered physical-chemical and microbiological analyzes are within the terms of Ordinance No. 2914/11. We recommend carrying out periodic control and monitoring of water quality, preventing the transmission of diseases.

References

Baird, R. B., Eaton, A. D., & Clesceri, L. S. (2012). Standard methods for the examination of water and wastewater (Vol. 10). E. W. Rice (Ed.). Washington, DC: American Public Health Association.

Bernardo, L., & Paz, L. P. S. (2008). Seleção de tecnologias de tratamento de água. São Carlos–SP: Ed. LDiBe, 1, 817-1016.

Brasil. (2011). Ministério da Saúde. Portaria nº 2.914, de 12 de dezembro de 2011. Dispõe sobre os procedimentos de controle e de vigilância da qualidade da água para consumo humano e seu padrão de potabilidade. Diário Oficial da República Federativa do Brasil.

Bufon, A. G. M., & Landim, P. M. B. (2019). Análise da qualidade da água por metodologia estatística multivariada na represa velha (CEPTA/IBAMA/Pirassununga/SP). Holos Environment, 7(1), 42-59.

Lima, S. C. A., & Santos, C. A. B. (2017). Educação e saúde pública: determinação de cloro e escherichia coli, na água utilizada para consumo no ifpe, campus afogados da ingazeira. Revista Ouricuri, 6(2), 029-041.

Merten, G. H., & Minella, J. P. (2002). Qualidade da água em bacias hidrográficas rurais: um desafio atual para a sobrevivência futura. Agroecologia e desenvolvimento rural sustentável, 3(4), 33-38.

Parron, L. M., Muniz, H. D. F., & Pereira, C. M. (2011). Manual de procedimentos de amostragem e análise físico-química de água. Embrapa Florestas-Documentos (INFOTECA-E).

Rand, M. C., Greenberg, A. E., & Taras, M. J. (1976). Standard methods for the examination of water and wastewater. Prepared and published jointly by American Public Health Association, American Water Works Association, and Water Pollution Control Federation..

Rocha, E. S., Rosico, F. S., Silva, F. L., Luz, T. C. S. D., & Fortuna, J. L. (2010). Análise microbiológica da água de cozinhas e/ou cantinas das instituições de ensino do município de Teixeira de Freitas (BA). Revista Baiana de Saúde Pública, 34(3), 694-705.

Salgado, S. R. T. (2008). Estudo dos parâmetros do decaimento do cloro residual em sistema de distribuição de água tratada considerando vazamento (Doctoral dissertation, Universidade de São Paulo).

Silva, S. P., Mendes, L. F., Dantas Fernandes, A. J., Ferreira, G. P., & Lúcio, M. M. L. M. (2012). Avaliação dos parâmetros sentinelas de qualidade da água de abastecimento das escolas municipais de Cabedelo/PB. In VII CONNEPI-Congresso Norte Nordeste de Pesquisa e Inovação.

Published

12/03/2020

How to Cite

ALMEIDA, R. L. J.; SANTOS, N. C.; PEREIRA, T. dos S.; SILVA, V. M. de alcântara; RIBEIRO, V. H. de A.; SILVA, L. R. I. da; MUNIZ, C. E. de S.; MOREIRA, F. I. N.; PINHEIRO, W. S.; EDUARDO, R. da S. Physical-chemical and microbiological analysis of water reservoirs for industrial supply. Research, Society and Development, [S. l.], v. 9, n. 4, p. e07942795, 2020. DOI: 10.33448/rsd-v9i4.2795. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/2795. Acesso em: 26 dec. 2024.

Issue

Section

Agrarian and Biological Sciences