Digital flow in the dental office and CAD/CAM system: 3 year-control

Authors

DOI:

https://doi.org/10.33448/rsd-v11i16.36196

Keywords:

CAD/CAM; Ceramic ; Dental veneers.

Abstract

Objective: The goals for this study were to present the history of the CAD/CAM system and the advantages of this system and other technological innovations in the clinician's daily dental practice. In addition to presenting a case report of a patient's treatment performed through DSD planning. Methodology: The entire aesthetic planning was demonstrated using the DSD and the patient additive mockup technique. After obtaining the 3D model, digital aesthetic planning was performed. In the manufacture of ceramic veneers, the CAD/CAM system was used. Then, the gingival removal and subsequent intra-oral scanning of the prepared region were performed. Photo-activatable adhesive cementation was used in the placement of the ceramic veneers, in addition to receiving a surface treatment, followed by the application of the adhesive system. Results: The result met the expectations of the patient, who was able to visualize the forecast of the final result. Conclusion: It was concluded that, although the CAD/CAM system has advantages, it is necessary for the professional's higher learning curve, with both techniques, both digital and analog, being adequate and efficient.

References

Alghazzawi T. F. (2016) . Advancements in CAD/CAM technology: Options for practical implementation. J Prosthodont Res. 6(2): 72-84.

Abduo J., Lyons K. & Bennamoun M. (2014). Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. International Journal of Dentistry.(1): 1-15.

Bernardes S. R., Tiossi, R. & Sartori, I. A. M., et al. (2012). Tecnologia CAD/CAM aplicada a prótese dentária e sobre implantes: o que é, como funciona, vantagens e limitações - uma revisão crítica da literatura. Journal ILAPEO. 6(1): 8-13.

Brawek P. K, Wolfart S., Endres L., et al. (2013). The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems. Clin Oral Investig. 17(9): 2119-2125.

Bindl A. & Mörmman W. H. (2003). Clinical and SEM evaluation of all ceramic chair-side CAD/CAM-generated partial crowns. European Journal of Oral Sciences. 111(2): 163-169.

Bosch G., Ender A. & Mehl A. (2014). A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes. Journal of Prosthetic Dentistry. 112(6): 1425-1431.

Cattoni F., Mastrangelo F. & Gherlone E. F., et al. (2016). A new total digital smile planning technique (3D-DSP) to fabricate CAD/CAM mockups for esthetic crowns and veneers. International Journal of Dentistry. 2016(1):1-5.

Cervino G., Fiorillo L. & Arzukanyan A. V., et al. (2019). Dental restorative digital workflow: Digital Smile Design from aesthetic to function. Dentistry Journal. 30(7): 1-12.

Coachman C. & Calamita M. C. (2012). Digital smile design: A tool for treatment planning and communication in esthetic dentistry. Quintessence Den Technol. 35:01-09.

Coachman C., Eric V. & Dooren, G. G., et al. (2012). Smile Design: From digital treatment planning to clinical reality. In: Cohen M (ed). Interdisciplinary treatment planning, Comprehensive Case Studies. Quintessence. 2: 119-174.

Costa J. B., Pelogia F. & Hagedorn B., et al. (2010). Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D. Oper Dent. 35(3): 324-329.

Eleutério D. (2019). The moment of 3D printing in dentistry. Prosthes Esthet Sci. 8(31): 63-68.

Ferreira, J. M., Santos, A. C. M. & Nogueira, P. L., et al. (2020). Estética dental por meio do uso de coroa e facetas metal free: relato de caso. Rev. Eletrônica Acervo Saúde. 56(56): 01-09.

Filgueiras A., Pinto D. G. & Ferrarez, L. L., et al. (2018). Aplicabilidade clínica dos avanços da tecnologia CAD-CAM em Odontologia. HU Revista. 44(1): 29-34.

Garcia L.O. R, Santos, F. P. & Passos, L. F., et al. (2020). Fluxo híbrido: a odontologia analógica e digital caminhando em sintonia no curso de odontologia do Centro Universitário. Ciência Atual. 15(1): 90-95.

Garcia P. P., da Costa R. G., Calgaro M., et al. (2018). Digital smile design and mock-up technique for esthetic treatment planning with porcelain laminate veneers. Journal of Conservative Dentistry. 21(4): 455-458.

Goujat A., Abouelleil H. & Colon P., et al. (2018). Marginal and internal fit of CAD/CAM inlay/onlay restorations: a systematic review of in vitro studies. The journal of prosthetic dentistry. 121(4): 590-597.

Grünheid T., Mccarthy S. D. & Larson B. E. (2014). Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance. Am J Orthod Dentofacial Orthop. 146(5): 673-682.

Haddadi Y., Bahrami G. & Isidor F. (2019). Accuracy of intra-oral scans compared to conventional impression in vitro. Primary Dental Journal. 8(3): 34-9.

Moura R. B. B. & Santos T. C. (2015). Sistemas cerâmicos metal free: tecnologia CAD/CAM – revisão de literatura. Revista interdisciplinar. 8(1): 220-226.

Noort R. V. The future of dental devices is digital. (2012). Dental Materials Journal. 28(1): 3-12.

Omar D. & Duarte C. (2017). The application of parameters for comprehensive smile esthetics by digital smile design programs: A review of literature. Saudi Dental Journal. 30(1): 7-12.

Stanley M., Paz A. G. & Miguel I., et al. (2018). Fully digital workflow, integrating dental scan, smile design and CAD/CAM: case report. BMC Oral Health. 134(18): 1-8.

Syrek A., Reich G. & Ranftl D., et al. (2010). J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent. 38(7): 553-559.

Ting-Shu S. & Jian, S. (2015). Intraoral digital impression technique: a review. Journal of Prosthodontics. 24(4): 313-321.

Wittneben J. G., Wright R. F. & Weber H. P., et al. (2009). A systematic review of the clinical performance of CAD/CAM single-tooth restorations.The International journal of prosthodontics. 22(5): 466-471.

Downloads

Published

16/12/2022

How to Cite

ZICA, J. de S. S.; COSTA, L. C. M.; MONTIJO, S. de P. Digital flow in the dental office and CAD/CAM system: 3 year-control . Research, Society and Development, [S. l.], v. 11, n. 16, p. e529111636196, 2022. DOI: 10.33448/rsd-v11i16.36196. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/36196. Acesso em: 20 apr. 2024.

Issue

Section

Health Sciences