The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report

Authors

DOI:

https://doi.org/10.33448/rsd-v9i12.10692

Keywords:

Removable Partial Denture; 3D Printing; Computer Aided Design; Vertical Dimension of Occlusion.

Abstract

The objective of this case report was to describe the clinical sequence for occlusal vertical dimension (OVD) recovering with the manufacture of removable partial dentures (RPD) produced by computer-aided design and rapid prototyping. The patient presented to the Dentistry Department of the Federal University of Rio Grande do Norte reporting dissatisfaction with the superior RPD. At clinical investigation, a fracture in the minor connector and support at the region of tooth 15 was observed, in addition to severe OVD loss. In this case, after obtaining correct OVD, four more sessions were necessary for RPD fabrication. In the first appointment, intraoral scanning was performed to generate STL files used for path of insertion determination in the CAD software. The need for a guide plane on tooth 15 was observed, thus a preparation guide was designed and 3Dprinted to aid axial tooth reduction. At the second visit, after mouth preparation, another intraoral scanning was performed to acquire virtual working models. The RPD framework was designed and 3D printed in a castable resin pattern and invested for cobalt-chromium alloy melting. In the third visit, clinical evaluation of the framework and teeth and artificial gingiva colors selection were performed. The articulated models were then 3D printed, enabling pre-fabricated teeth to be assembled and acrylized. On the fourth appointment, RPD was installed and the patient received routine instructions. In this sense, the use of CAD/CAM technologies presented as a valuable tool to enhance restoration of OVD by the manufacturing of RPD.

References

Arnold, C., Hey, J., Schweyen, R. & Setz, J.M. (2018). Accuracy of CAD-CAM-fabricated removable partial dentures. J Prosthet Dent, 119(4), 586-92. doi: 10.1016/j.prosdent.2017.04.017.

Arafa, K.A.O. (2018). Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology. Saudi Med J, 39(1), 17-22. doi: 10.15537/smj.2018.1.20796.

Campbell, S.D., Cooper, L., Craddock, H., Hyde, T.P., Nattress, B., Pavitt, S.H. & Seymour, D.W. (2017). Removable partial dentures: The clinical need for innovation. J Prosthet Dent, 118(3), 273-280. doi: 10.1016/j.prosdent.2017.01.008.

Chen, H., Li, H., Zhao, Y., Zhang, X., Wang, Y. & Lyu, P. (2019). Adaptation of removable partial denture frameworks fabricated by selective laser melting. J Prosthet Dent, 122(3), 316-324. doi: 10.1016/j.prosdent.2018.11.010.

Carneiro Pereira, A.L., Bezerra de Medeiros, A.K., de Sousa Santos, K., Oliveira de Almeida, É., Seabra Barbosa, G.A. & da Fonte Porto Carreiro, A. (2020). Accuracy of CAD-CAM systems for removable partial denture framework fabrication: A systematic review. J Prosthet Dent, S0022-3913(20), 30018-4. doi: 10.1016/j.prosdent.2020.01.003.

Gimenez, B., Ozcan, M., Martinez-Rus, F. & Pradies, G. (2015). Accuracy of a digital impression system based on active triangulation technology with blue light for implants: effect of clinically relevant parameters. Implant Dent, 24(5), 498-504. doi: 10.1097/ID.0000000000000283.

Hayama, H., Fueki, K., Wadachi, J. & Wakabayashi, N. (2018). Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible. J Prosthodont Res, 62(3), 347-52. doi: 10.1016/j.jpor.2018.01.003.

Hu, F., Pei, Z. & Wen, Y. (2019). Using intraoral scanning technology for three-dimensional printing of kennedy class I removable partial denture metal framewotk: a clinical report. J Prosthodont, 28(2), 473-476. doi: 10.1111/jopr.12712.

Hamanaka, I., Isshi, K., & Takahashi, Y. (2018). Fabrication of a nonmetal clasp denture supported by an intraoral scanner and CAD-CAM. J Prosthet Dent, 120(1), 9-12. doi: 10.1016/j.prosdent.2017.09.011.

Kattadiyil, M.T., Jekki, R., Goodacre, C.J. & Baba, N.Z. (2015). Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent, 114(6), 818-25. doi: 10.1016/j.prosdent.2015.08.001.

Koutsoukis, T., Zinelis, S., Eliades, G., Al-Wazzan, K., Rifaiy, M.A. & Al Jabbari, Y.S. (2015). Selective Laser Melting Technique of Co-Cr Dental Alloys: A Review of Structure and Properties and Comparative Analysis with Other Available Techniques. J Prosthodont, 24(4), 303-12. doi: 10.1111/jopr.12268.

Kattadiyil, M.T., Mursic, Z., AlRumaih, H. & Goodacre, C.J. (2014). Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent, 112(3), 444-8. doi: 10.1016/j.prosdent.2014.03.022.

Lúcia, V.O. (1964). A technique for recording centric relation. J Prosthet Dent, 14(3), 492-505.

Lee, J-W., Park, J-M., Park, E-J., Heo, S-J., Koak, J-Y. & Kim S-K. (2017). Accuracy of a digital removable partial denture fabricated by casting a rapid prototyped pattern: A clinical study. J Prosthet Dent, 118(4), 468-474. doi: 10.1016/j.prosdent.2016.12.007.

Lee, H. & Kwon, K.R. (2019). A CAD-CAM device for preparing guide planes for removable partial dentures: A dental technique. J Prosthet Dent, 122(1), 10-13. doi: 10.1016/j.prosdent.2018.06.011.

Loney, R.W., Lee, C.J. & Michaud, P.L. (2017). Digital scanning to aid guiding plane and rest seat preparations for removable partial dentures. J Prosthet Dent, 118(5), 581-583. doi: 10.1016/j.prosdent.2017.01.020.

Lang, L.A. & Tulunoglu, I. (2014). A Critically Appraised Topic Review of Computer-Aided Design/Computer-Aided Machining of Removable Partial Denture Frameworks. Dent Clin of North Am, 58(1), 247-55. doi: 10.1016/j.cden.2013.09.006.

Marghalani, A., Weber, H.P., Finkelman, M., Kudara, Y., El Rafie, K. & Papaspyridakos P. (2018). Digital versus conventional implant impressions for partially edentulous arches: An evaluation of accuracy. J Prosthet Dent, 119(4), 574-579. doi: 10.1016/j.prosdent.2017.07.002.

Mansour, M., Sanchez, E. & Machado, C. (2016). The Use of Digital Impressions to Fabricate ToothSupported Partial Removable Dental Prostheses: A Clinical Report. J Prosthodont, 25(6), 495-7. doi: 10.1111/jopr.12346.

Mendes, T.A., Marques, D.; Lopes, L.P. & Caramês, J. (2019). Total digital workflow in the fabrication of a partial removable dental prostheses: a case report. Open Med Case Rep, 17(7), 2050313X19871131. doi: 10.1177/2050313X19871131.

Nishiyama, H., Taniguchi, A., Tanaka, S. & Baba, K. (2020). Novel full digital workflow for removable partial denture fabrication. J Prosthodont Res, 64(1), 98-103. doi: 10.1016/j.jpor.2019.05.002.

Pereira, A.L.C., de Aquino, L.M.M., de Freitas, R.F.C.P., Tôrres, A.C.P. & Carreiro, A.F.P. (2019). CAD/CAM-fabricated removable partial dentures: a case report. Int J Comput Dent, 22(4), 371-379.

Soltanzadeh, P., Suprono, M.S., Kattadiyil, M.T., Goodacre, C. & Gregorius, W. (2019). An in vitro investigation of accuracy and fit of conventional and CAD/CAM removable partial denture frameworks. J Prosthodont, 28:547-55. doi: 10.1111/jopr.12997.

Tregerman, I., Renne, W., Kelly, A. & Wilson D. (2019). Evaluation of removable partial denture frameworks fabricated using 3 different techniques. J Prosthet Dent, 122(4), 390-395. doi: 10.1016/j.prosdent.2018.10.013.

Takahashi, Y., Hamanaka, I. & Isshi, K. (2017). CAD/CAM-fabricated nonmetal clasp denture: In vitro pilot study. Int J Prosthodont, 30(3), 277-279. doi: 10.11607/ijp.5158.

Virard, F., Venet, L., Richert, R., Pfeffer, D., Viguie, G., Bienfait A, et al. (2018). Manufacturing of an immediate removable partial denture with an intraoral scanner and CAD-CAM technology: a case report. BMC Oral Health, 18(1), 120. doi: 10.1186/s12903-018-0578-3.

Ye, H., Li, X., Wang, G., Kang, J., Liu, Y., Sun, Y. et al. (2018). A Novel Computer-Aided Design/Computer-Assisted Manufacture Method for One-Piece Removable Partial Denture and Evaluation of Fit. Int J Prosthodont, 31(2), 149-151. doi: 10.11607/ijp.5508.

Downloads

Published

14/12/2020

How to Cite

CARREIRO, A. da F. P. .; PEREIRA, A. L. C.; PAZ, C. O. .; CARDOSO, R. G. .; MEDEIROS, C. R. P. .; MEDEIROS, A. K. B. de .; FREITAS , R. F. C. P. de . The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report. Research, Society and Development, [S. l.], v. 9, n. 12, p. e9891210692, 2020. DOI: 10.33448/rsd-v9i12.10692. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/10692. Acesso em: 22 nov. 2024.

Issue

Section

Health Sciences