Non-invasive versus invasive method to measure blood pressure in rodents: an integrative literature review

Authors

DOI:

https://doi.org/10.33448/rsd-v11i8.30789

Keywords:

Blood pressure measurement; Rodents; Invasive methods; Non-Invasive methods.

Abstract

Blood pressure (BP) measurement is the main monitoring parameter related to the cardiac system, and the use of animals is vital for understanding the physiological mechanism and studying pathologies related to this system. The most recommended measurement procedures in rodents in the literature are: The non-invasive method (tail cuff) and the invasive methods (catheter with fluid and telemetry). The objective of this study was to verify the main arterial measurement techniques in rodents, evaluate their positive and negative points and classify which is the most viable and effective technique for initial experimental tests. An integrative literature review was carried out using the descriptors and their respective synonyms, “real time device”, “blood pressure measurements”, “rats” using the Boolean “AND” in PubMed, Scielo and Medline databases. As inclusion criteria, articles that addressed the aforementioned theme, in Portuguese, English or Spanish, complete, from experimental trials on rodents, published within the last 21 years were adopted. As exclusion criteria were articles that were not available for full reading and studies that did not use rodents as a sample. Thirteen articles were selected that met the criteria. The results demonstrate that invasive methods can be advantageous for continuous measurements, but that it would be preferable to use the non-invasive method as it is safer and easier to perform. It is concluded that for initial experimental trials, the procedure to be chosen would be the non-invasive method, tail cuff.

References

Drüeke, T. B, & Devuyst, O. (2019). Blood pressure measurement in mice: tail-cuff or telemetry?. Kidney International, 96(1), 36.

Egner, B. (2015). High Definition Oscillometry: non-invasive blood pressure measurement and pulse wave analysis. Principles Of Safety Pharmacology. 243-264.

Erken, H. A, Erken, G, & Genç, O. (2012). Blood Pressure Measurement in Freely Moving Rats by the Tail Cuff Method. Clinical And Experimental Hypertension, 35(1), 11-15.

Ferreira, L. B. D, Cesaretti, M. L. R, Voltera, A. F, Ginoza, M, & Kohlmann J. (2011). O. Efeito da sobreposição de um modelo de obesidade neuroendócrina experimental e hipertensão arterial sobre a pressão arterial, peso corporal e parâmetros metabólicos e renais de ratos. Jornal Brasileiro de Nefrologia, 3(33), 338-344.

Fraser, T. B, Wturner, S, Mangos, G. J, Ludbrook, J, & Awhitworth, J. (2001). Comparison of telemetric and tail-cuff blood pressure monitoring in adrenocorticotrophic hormone-treated rats. Clinical And Experimental Pharmacology And Physiology, 1(28), 831-835.

Gao, Y, Yang, J, & Wang, S. (2016). Effects of telemetry implantation surgery on blood pressure and its underlying mechanism. Clinical And Experimental Hypertension, 38(4), 359-364.

Hoorn, E. J, Mccormick, J. A, & Ellison, D. H. (2011). High Tail-Cuff Blood Pressure in Mice 1 Week After Shipping: the need for longer acclimation. American Journal Of Hypertension, 24(5), 534-536.

Hu, S, Chen, H, Jia, S, Xiao, X, Cao, Y, & Wang, W. (2020). A wireless passive extra-arterial implantable blood pressure monitoring sensing system for rats. Microsystem Technologies, 27(7), 2595-2603.

Ibrahim, J, Berk, B. C, & Hughes, A. D. (2006). Comparison of Simultaneous Measurements of Blood Pressure by Tail-Cuff and Carotid Arterial Methods in Conscious Spontaneously Hypertensive and Wistar-Kyoto Rats. Clinical And Experimental Hypertension, 28(1), 57-72.

Kramer, K, & Remie, R. (2005). Measuring Blood Pressure in Small Laboratory Animals. Methods In Molecular Medicine, 108(1), 51-62.

Kubota, Y, Umegaki, K, Kagota, S, Tanaka, N, Nakamura, K, Kunitomo, M, & Shinozuka, K. (2006). Evaluation of Blood Pressure Measured by Tail-Cuff Methods (without Heating) in Spontaneously Hypertensive Rats. Biol. Pharm. Bull, 8(29), 1756-1758.

Kumar, P, Rawat, A, Tiwari, S, & Gangwar, A. (2014). Noninvasive measurement of systolic blood pressure in rats: a novel technique. Indian Journal Of Pharmacology, 46(3), 351.

Luft, F. C. (2019). Men, mice, and blood pressure: telemetry?. Kidney International, 96(1), 31-33.

Luther, J. M, & Fogo, A. B. (2019). Under pressure—how to assess blood pressure in rodents: tail-cuff?. Kidney International, 96(1), 34-36.

Olvera, J. B, Rios, R. A. O, & Camacho, R. R. (2018). Blood pressure measurement system based on oscillometric method. Pistas Educativas, 39(128), 248-265.

Pauline, M, Avadhany, S. T, & Maruthy, K.N. (2011). Non Invasive Measurement of Systolic Blood Pressure in Rats: A Simple Technique. Al Ame En J Med Sci, 4(4), 365-369.

Tsubone, H, Makimura, Y, Hanafusa, M, Yamamoto, Y, Tsuru, Y, Motoi, M, & Amano, S. (2014). Agaricus brasiliensis KA21 Improves Circulatory Functions in Spontaneously Hypertensive Rats. Journal of medicinal food, 17(3), 295-301.

Van vliet, B. N, Chafe, L. L, Antic, V, Schnyder-candrian, S, & Montani, J. (2000). Direct and indirect methods used to study arterial blood pressure. Journal Of Pharmacological And Toxicological Methods, 1(44), 361-373.

Wilde, E, Aubdool, A. A, Thakore, P, Baldissera, L, Alawi, K. M, Keeble, J, Nandi, M, & Brain, S. D. (2017). Tail‐Cuff Technique and Its Influence on Central Blood Pressure in the Mouse. Journal Of The American Heart Association, 6(6), 1-15.

Zhao, X, Ho, D, Gao, S, Hong, C, Vatner, D. E, & Vatner, Stephen F. (2011). Arterial Pressure Monitoring in Mice. Current Protocols In Mouse Biology, 105-122.

Zwijnenberg, R. J, Rio, C. L, Ueyama, Y, Muir, W. W. (2011). Evaluation of oscillometric and vascular access port arterial blood pressure measurement techniques versus implanted telemetry in anesthetized cats. Ajvr, 72(8), 1015-1021.

Published

08/06/2022

How to Cite

VALÉRIO, M. da P.; MARTINI, S. C. .; BOSCHI, S. R. M. da S. .; SCARDOVELLI, T. A. .; SILVA, A. P. da . Non-invasive versus invasive method to measure blood pressure in rodents: an integrative literature review. Research, Society and Development, [S. l.], v. 11, n. 8, p. e4911830789, 2022. DOI: 10.33448/rsd-v11i8.30789. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/30789. Acesso em: 23 nov. 2024.

Issue

Section

Review Article