Ultrasonic inserts in channel cleaning with fiber posts: in vitro study

Authors

DOI:

https://doi.org/10.33448/rsd-v10i2.9536

Keywords:

Ultrasonic Insert; Fiberglass pins; Endodontic retreatment.

Abstract

Currently, the choice of an adequate restoration of endodontically treated teeth is guided in part by the aesthetic requirement. Intraradicular pins are used when the dental remnant does not have adequate support for retention. In view of the difficulties in removing the fiberglass pins. The objective of this work, in vitro, was to compare two techniques of fiberglass pin wear to unclog root canals. Materials and Methods: the time to remove the fiberglass pin was evaluated. 26 standard single-toothed teeth were selected in 15 mm real working length (CRT). The chemical-mechanical preparation was carried out with the universal Protaper system. After filling, 10 mm of the canal was cleared, leaving 5 mm of material remaining in the apical third. The pins were cemented according to the manufacturer's guidelines. The teeth were divided into two groups for the removal of the pin: In Group 01 (G1), the wear of up to 7 mm of the pin was performed using a multilaminated spherical drill No. 1 (LN), in low rotation, associated with the ultrasonic insert - conical TRI 01 DA3, under refrigeration, to wear the remaining pin. In Group 02 (G2) the wear of the pin was made using the PERIOSUB smooth trunk-conical ultrasonic insert, under refrigeration. Timing was performed during the removal of the fiberglass pin, where G1 obtained an average of 290 seconds and G2 with an average of 753 seconds, which was statistically significant (unpaired t test p ˂ 0.05). The G1 group had a shorter time for removing the fiberglass pin when compared to G2. The best option for removing the fiberglass pin seems to be the association of the spherical drill followed by the ultrasonic insert in the removal of fiberglass pins.

Author Biography

Esdras Gabriel Alves-Silva, Universidade Estadual de Campinas

Departamento da Odontologia Restauradora, área da Endodontia, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas FOP/UNICAMP

References

Araújo-Reis, C., Araújo, S. S., Baratto-Filho, F., Reis, L. C., & Fidel, S. R. (2009). Comparação da infiltração apical entre os cimentos obturadores AH Plus, Sealapex, Sealer 26 e Endofill por meio da diafanização. Rsbo. 1(6):21-28.

Artopoulou, I. I., O’Keefe, K. L., & Powers, J. M. (2006). Effect of core diameter and surface treatment on the retention of resin composite cores to prefabricated endodontic posts. J Prosthodon. 15(3):172-9.

Balbosh, A., Kern, M. Effect of surface treatment on retention of glass-fiber endodontic posts. J Prosthet Dent (2006). 95(3):218-23.

Benassi, M., Freire, R. M., Macedo, M. C., & Cardoso, R. J. A. (2008). Avaliação da superfície dentinária com o microscópio clínico após remoção de retentor intra-radicular utilizando o ultra-som. RGO. 56(3):267-273.

Braga, N. M. A., Alfredo, E., Vansan, L. P., Fonseca, T. S., Ferraz, J. A. B., & Sousa-Neto, M. D. (2005). Efficacy of ultrasound in removal of intraradicular posts using diferente techniques. J Oral Sci; 47(3):117-21.

Coelho, E. T., & Sousa, T. L. P. Pinos de fibra de vidro: Protocolos de desobstrução no retratamento endodôntico.40 f. TCC (Graduação) - Curso de Odontologia, Universidade Potiguar, Natal, 2012.

Fracassi, L. D., Ferraz, E. G., Albergaria, S. J., & Sarmento, V. A. (2010). Comparação radiográfica do preenchimento do canal radicular de dentes obturados por diferentes técnicas endodônticas. Rev Gaúcha Odontol., 58(2): 173-179.

Garrido, A. D. B. Avaliação de diferentes protocolos de aplicação de ultra-som para remoção de retentores intraradiculares fundidos fixados com cimento de fosfato de zinco. 2007. 107 f. Tese (Doutorado) - Curso de Odontologia, Universidade de Ribeirão Preto, Ribeirão Preto, 2007.

Gesi, A., Magnolfi, S., Goracci, C., & Ferrari, M. (2003). Comparison of two techniques for removing fiber posts. J Endod. 29(9): 580-2.

Gonçalves, B. E. M., Silva, S. J. A., Da-Araújo, R. P. C. (2012). Avaliação da eficácia obturadora do Coltosol® e do IRM® no selamento provisório de dentes sob intervenção endodôntica. R. Ci. med. biol. 11(2): 154-158.

Goodacre, C. J. (2010). Carbon fiber posts may have fewer failures than metal posts. J Evid Base Dent Pract; 10(3): 32-4.

Kalkan, M., Usumez, A., Ozturk, N. A., Belli, S., Eskitascioglu, G. (2006). Bond strength between root dentin and three glass-fiber post systems. J Prosthet Dent. 96(1):41-6.

Kim, J. J., Alapati, S., Knoernschild, K. L., Jeong, Y. H., Kim, D. G., & Lee, D. J. (2016). Micro-computed tomography of tooth volume changes following post removal. J Prosthodon. 1-7.

Lindemann, M., Yaman, P., Dennison, J. B., & Herrero, A. A. (2005). Comparison of the efficiency and effectiveness of various techniques for removal of fiber posts. J. Endod. 31(7):520-522.

Lopes, H. P., & Siqueira Junior, J. F. (2010). Endodontia: Biologia e técnica. (3a ed.), Editora Guanabara Koogan.

Muniz, L. (2005). Novo conceito para retenção intra-radicular: Preparo endodôntico para pinos de fibra. R Dental Press Estét. 2(1):70-8.

Oliveira, A. C. M., & Duque, C. (2012). Métodos de avaliação da resistência à infiltração em obturações endodônticas. Revista Brasileira de Odontologia. 69(1): 34-38.

Pereira, A. D., Shitisuka, D. M., Parreira, F. J., & Shitsuka, A. R. Metodologia de pesquisa cientifica. UFSM. https://www.ufsm.br/orgaos-suplementares/nte/wpcontent/uploads/sites/358/2019/02/Metodologia-da-Pesquisa-Cientifica_final.pdf.

Rijk, W. G. Removal of fiber posts from endodontically treated teeth. American J Dent. 13(2):19-21.

Rocha, I. A. R. Avaliação da eficácia e eficiência na remoção de pino de fibra de vidro. 20p. Monografia – Faculdade de Odontologia UFBA. Salvador/BA

Rossi, M. Técnicas para remoção de pinos intra-radiculares.2008. 33p. Dissertação (Especialização) – Faculdade Ingá, UNINGÁ, Passo Fundo/RS.

Silva, E. J., Neves, A. A., De-Deus, G., Accorsi-Mendonça, T., Moraes, A. P., Valentim, R. M., & Moreira, E. J. (2015). Cytotoxicity and gelatinolytic activity of a new silicon-based endodontic sealer. J Appl Biomater Funct Mater. 13(4):376-80.

Soares, J. A., Brito-Júnior, M., Fonseca, D. R., Melo, A. F., Santos, S. M. C., Sotomayor, N. D. C. S., et al. (2009). Influence of luting agents on time required for cast post removal by ultrasound: an in vitro study. J Appl Oral Sci. 17(3):145-9

Published

19/02/2021

How to Cite

ALVES-SILVA, E. G.; MEDEIROS, J. B. G. de .; MEDEIROS, W. D. de .; DAMETTO, F. R. .; ARRUDA-VASCONCELOS, R. .; LOUZADA, L. M. .; GOMES, B. P. F. de A. .; GADÊ-NETO, C. R. . Ultrasonic inserts in channel cleaning with fiber posts: in vitro study. Research, Society and Development, [S. l.], v. 10, n. 2, p. e3481029536, 2021. DOI: 10.33448/rsd-v10i2.9536. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/9536. Acesso em: 23 nov. 2024.

Issue

Section

Health Sciences