Reciproc Blue x V-File: a study on the performance of two reciprocant instruments after third use
DOI:
https://doi.org/10.33448/rsd-v10i15.22849Keywords:
Instrumentation; Endodontic files; Root canals; Reciprocating instruments; Reciproc Blue; V-file.Abstract
Objective: The cleaning and shaping of root canals is undeniably a step of great importance for the success of endodontic treatment. With the aim of optimizing the time and quality of this step, numerous instruments of different materials and shapes have been developed over the years. One of these instruments was nickel-titanium files, which have greater flexibility and resistance, allowing a better prognosis for endodontic treatment. In this study, two endodontic files, Reciproc Blue and V-File, were compared with the aim of evaluating their performance after the third use. Materials and methods: 60 acrylic blocks wrapped with laminated paper and filled with Nankin ink were used. Instrumentation was performed with an endodontic engine, by an experienced operator. After instrumentation, the blocks were photographed so that the photographs were superimposed. Results: After statistical analysis, it was found that there was no significant difference in the performance of the two groups after the third use. Conclusion: There was no significant difference between the two studied groups, and both are safe for the preparation of curved canals, but it is necessary that the manufacturer's recommendation is followed, regarding the number of canals instrumented with the same file.
References
Almeida, G. C., Guimarães, L. C., Resende, P. D., Buono, V. T. L., Peixoto, I. F. C., & Viana, A. C. D. (2019). Torsional behaviour of Reciproc and Reciproc blue instruments associated with their martensitic transformation temperatures. International endodontic journal, 52(12), 1768-1772.
Cerqueira, L. G., Gomes, C. C., Penina, P., Prado, M. A., Freitas, L. F., Camões, I. C. G., & Fidel, R. (2007). Técnicas de instrumentação manual e rotatória: comparação da modelagem dos canais radiculares. Revista Brasileira de Pesquisa em Saúde/Brazilian Journal of Health Research.
De-Deus, G., Silva, E. J. N. L., Vieira, V. T. L., Belladonna, F. G., Elias, C. N., Plotino, G., & Grande, N. M. (2017). Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. Journal of endodontics, 43(3), 462-466.
Fernandes, C., Cardoso, R., Hilgenberg, S. P., Frozoni, M., Mendez, E. C., Braitt, A. H., ... & da Silva Limoeiro, A. G. (2020). Análise comparativa da qualidade da instrumentação de limas manuais em canais simulados: K-flexofile e ProDesign M. Brazilian Journal of Health Review, 3(6), 18854-18863.
Farias, A. L. V. (2020). Eficácia das limas reciprocantes Reciproc Blue e Prodesign R na remoção de material obturador: uma revisão integrativa da literatura.
Keskin, C., Demiral, M., & Sarıyılmaz, E. (2018). Comparison of the shaping ability of novel thermally treated reciprocating instruments. Restorative dentistry & endodontics, 43(2).
Keskin, C., Inan, U., Demiral, M., & Keleş, A. (2017). Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. Journal of endodontics, 43(8), 1360-1363.
Lim, Y. J., Park, S. J., Kim, H. C., & Min, K. S. (2013). Comparison of the centering ability of Wave· One and Reciproc nickel-titanium instruments in simulated curved canals. Restorative dentistry & endodontics, 38(1), 21-25.
Medeiros, J. M. F., Haddad Filho, M. S., Habitante, S. M., da Rosa, L. C. L., Salum, G., & Almeida, E. T. D. C. (2017). Perda de corte da lima protaper quanto a esterilização e número de uso. Revista de Odontologia da Universidade Cidade de São Paulo, 23(3), 228-237.
Özyürek, T., Gündoğar, M., Uslu, G., Yılmaz, K., Staffoli, S., Grande, N. M., ... & Polimeni, A. (2018). Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals. Odontology, 106(4), 408-413.
Pereira, H. S. C., da Silva, E. J. N. L., & de Souza Coutinho-Filho, T. (2013). Movimento reciprocante em Endodontia: revisão de literatura. Revista Brasileira de Odontologia, 69(2), 246.
Piazza, G. C., do Amaral Capello, P., Almeida, C. N., Blatt, J. A., & Ferreira, R. (2021). Avaliação do número de canais modelados com limas ProDesign M até sua fratura, simulados em blocos de resina acrílica. Orbis Science, 1(1), 46-56.
Silva, E. J. N. L., Vieira, V. T. L., Hecksher, F., dos Santos Oliveira, M. R. S., dos Santos Antunes, H., & Moreira, E. J. L. (2018). Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clinical oral investigations, 22(7), 2633-2638.
Silva, M. R., de Carvalho, A. D. M., Rodrigues, M. A., Souza, C. C., Rosas, C. A. P., Cardoso, R. M., & da Silva Limoeiro, A. G. (2021). Estudo In Vitro da limpeza de canais simulados (Wave One Gold x W-File). Research, Society and Development, 10 (13), e541101321693-e541101321693.
Silva, M.C.S., Simião, A.E.S., Souza C.C., Rodrigues, M.A., Oliveira Junior,E.S., Carvalho,A.M., Limoeiro.A.G. (2021). Avaliação da capacidade de modelagem de dois sistemas reciprocantes: Reciproc Blue x V-File. Research, Society and Development, 10 (15), e177101522870.
Schilder, H. (1974). Cleaning and shaping the root canal. Dent Clin North Am, 18, 269-296.
Topçuoğlu, H. S., & Topçuoğlu, G. (2017). Cyclic fatigue resistance of Reciproc Blue and Reciproc files in an S-shaped canal. Journal of endodontics, 43(10), 1679-1682.
Yared, G. (2008). Canal preparation using only one Ni‐Ti rotary instrument: preliminary observations. International endodontic journal, 41(4), 339-344.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Anna Elisa Souza Simeão; Maria Clara Santos Silva; Edeilton Santana de Oliveira Júnior e Bezerra ; Caio Cesar Souza; Adolfo de Matos de Carvalho ; Ana Grasiela Limoeiro
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
1) Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2) Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3) Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.