Due to the high use of animals as experimental models for pharmaceutical trials, especially rats, it is necessary to standardize reference values for the evaluation of liver perfil by the analytes alanine aminotransferase (ALT) and aspartate aminotransferase (AST) and renal function, through the analytes urea and creatinine. For this purpose, samples were collected from 169 samples of Rattus norvegicus of Wistar strain, from the Vivarium of the University of Franca (SP), provided of semi-automated analytical methodology. For the calculation of the value, mean and standard deviation were performed for standardization and for the creation of reference values, therefore -2DP for minimum value determination and + 2DP for maximum value were used. The liver enzyme ALT presented a reference range from 21 to 96 U / L, while the AST from 44 to 186 U / L. In renal markers, urea was 20 to 73 mg / dL and creatinine 0.23 to 0.77 mg / dL. Given the applied methodology and the results obtained, it is admitted that it is very important to standardize the reference values of analytes in animal houses due to geographical changes, protocols, diets, among others; In addition, reducing the use of animals in experimental procedures in addition to guiding researchers on animal health and assisting analysis in various experimental research projects.

Author Biographies

Silvio de Almeida Junior, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

Poliana Marques Pereira, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

Vanessa de Souza Totoli, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

Micaela Silva Carrijo, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

Fernanda Rafacho Badoco, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

Lucas de Freitas Pereira, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

Fernanda Gosuen Gonçalves Dias, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

Ricardo Andrade Furtado, University of Franca

Animal Science, University of Franca, Franca, São Paulo, Brazil

References

Almeida Jr, S. (2014). Fase pré-analítica em laboratório de análises clinicas. Semana Acadêmica Revista Científica, 1(68) 01-19. https://semanaacademica.org.br/artigo/fase-pre-analitica-em-laboratorio-de-analises-clinicas.

Almeida Jr, S, Rodrigues, A.A, and Costa, P.B.S. (2016). Transporte de material biológico aplicados ao laboratório de análises clínicas. Semana Acadêmica Revista Científica, 1(94) 01-10. https://semanaacademica.org.br/artigo/transporte-de-material-biologico-aplicados-ao-laboratorio-de-analises-clinicas.

Almeida Junior, S. de. (2019). In vivo methods for the evaluation of anti-inflammatory and antinoceptive potential. Brazilian Journal Of Pain, 2(4). https://doi.org/10.5935/2595-0118.20190070.

BRASIL (2005). Ministério da Saúde. Agência Nacional de Vigilância Sanitária (ANVISA). Dispõe sobre regulamentação técnica para funcionamento de laboratórios clínicos. Resolução da Diretoria Colegiada – RDC nº 302, 2005. http://portal.anvisa.gov.br/documents/10181/2718376/RDC_302_2005_COMP.pdf/7038e853-afae-4729-948b-ef6eb3931b19.

CAP (1998). College of American Pathologists. Commission on Laboratory Accreditation Inspection Checklist. Laboratory general. Northfield, IL. http://webapps.cap.org/apps/docs/laboratory_accreditation/checklists/laboratory_general_sep07.pdf.

Castello Branco, A. C. da S. (2011). Parâmetros bioquímicos e hematológicos de Ratos Wistar e Camundongos Swiss do biotério professor Thomas George. Revista Brasileira de Ciências da Saúde, 15(2), 209–214. https://doi.org/10.4034/RBCS/2011.15.02.11.

CLSI (2016). Statistical Quality Control for Quantitative Measurement Procedures: Principles and Definitions. 4th ed. CLSI guideline C24. Wayne, PA: Clinical and Laboratory Standards Institute. https://clsi.org/standards/products/clinical-chemistry-and-toxicology/documents/c24/.

Dantas, J. A., Ambiel, C. R., Cuman, R. K. N., Baroni, S., & Amado, C. A. B. (2008). Valores de referência de alguns parâmetros fisiológicos de ratos do Biotério Central da Universidade Estadual de Maringá, Estado do Paraná - DOI: 10.4025/actascihealthsci.v28i2.1099. Acta Scientiarum. Health Sciences, 28(2), 165–170. https://doi.org/10.4025/actascihealthsci.v28i2.1099.

Fagundes, D. J., & Taha, M. O. (2004). Modelo animal de doença: Critérios de escolha e espécies de animais de uso corrente. Acta Cirurgica Brasileira, 19(1), 59–65. https://doi.org/10.1590/S0102-86502004000100010.

Ferreira, C. E. dos S., & Andriolo, A. (2008). Intervalos de referência no laboratório clínico. Jornal Brasileiro de Patologia e Medicina Laboratorial, 44(1). https://doi.org/10.1590/S1676-24442008000100004.

JCAHO (1998). Joint Commission on Accreditation of Healthcare Organizations. Comprehensive accreditation manual for pathology and clinical laboratory services. Oakbrook Terrace, IL. https://www.jointcommission.org/accreditation-and-certification/health-care-settings/laboratory-services/learn/our-standards/.

Junior, S. de A., Cardoso-Brito, V., Moreira, M. E. S., Melo, M. R. S. de, Andrade, G., & Bulgo, D. C. (2020). Biosafety evaluation and characterization of occupational risks in a ready care unit paulista, Brazil. Research, Society and Development, 9(2), 74922028. https://doi.org/10.33448/rsd-v9i2.2028.

Lima, C. M., Lima, A. K., Melo, M. G. D., Dória, G. A. A., Serafini, M. R., Albuquerque-Júnor, R. L. C., & Araújo, A. A. S. (2014). Valores de referência hematológicos e bioquímicos de ratos (Rattus novergicus linhagem Wistar) provenientes do biotério da Universidade Tiradentes. Scientia Plena, 10(3). https://www.scientiaplena.org.br/sp/article/view/1784.

LIMA, F. E. G. (2018). Perfil bioquímico e hematológico de ratos e camundongos do biotério central da Universidade Federal do Ceará. 75 f. Dissertação (Mestrado Profissional em Farmacologia Clínica) - Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza. http://www.repositorio.ufc.br/handle/riufc/32198.

Lima-Oliveira, G. de S., Picheth, G., Sumita, N. M., and Scartezini, M. (2009). Controle da qualidade na coleta do espécime diagnóstico sanguíneo: Iluminando uma fase escura de erros pré-analíticos. Jornal Brasileiro de Patologia e Medicina Laboratorial, 45(6), 441–447. https://doi.org/10.1590/S1676-24442009000600002.

Melo, M. G. D., Dória, G. a. A., Serafini, M. R., & Araújo, A. a. S. (2013). Valores de referência hematológicos e bioquímicos de ratos (Rattus novergicus linhagem Wistar) provenientes do biotério central da Universidade Federal de Sergipe. Scientia Plena, 8(9). https://www.scientiaplena.org.br/sp/article/view/295

Plebani, M. (2009). Exploring the iceberg of errors in laboratory medicine. Clinica Chimica Acta; International Journal of Clinical Chemistry, 404(1), 16–23. https://doi.org/10.1016/j.cca.2009.03.022

Vieira, K. F., Shitara, E. S., Mendes, M. E., & Sumita, N. M. (2011). A utilidade dos indicadores da qualidade no gerenciamento de laboratórios clínicos. Jornal Brasileiro de Patologia e Medicina Laboratorial, 47(3), 201–210. https://doi.org/10.1590/S1676-24442011000300002

Downloads

Published

26/03/2020

How to Cite

ALMEIDA JUNIOR, S. de; PEREIRA, P. M.; TOTOLI, V. de S.; CARRIJO, M. S.; BADOCO, F. R.; PEREIRA, L. de F.; DIAS, F. G. G.; FURTADO, R. A. Validation of renal and hepatic profile parameters of rodents Rattus novergicus kept in the maintenance vivarium of the University of Franca. Research, Society and Development, [S. l.], v. 9, n. 5, p. e18952619, 2020. DOI: 10.33448/rsd-v9i5.2619. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/2619. Acesso em: 21 dec. 2024.

Issue

Section

Agrarian and Biological Sciences