Effectiveness of the WaveOne Gold system in preparing long oval canals with unique instruments and in sequential mode
DOI:
https://doi.org/10.33448/rsd-v10i5.15500Keywords:
X-ray; X-ray microtomography; Endodontics; Root canal preparation.Abstract
The aim of this study was to evaluate variation in volume, percentage of non-instrumented areas and debris after preparing long oval canals with the WaveOne® Gold (WOG) system with two techniques: using each instrument of the system (single-file - SF) or use of all files in the system sequentially (multiple-file - MF). Fifty lower human incisors were selected, distributed in five groups (n = 10). After verification of the root dimension with manual files, all specimens were submitted to microcomputed tomography (μCT) for analysis of volume variation, percentage of non-instrumented areas and debris after preparation. The specimens were prepared with WOG instruments, using SF and MF mode. The data were analyzed for normality and homogeneity of variance. Depending on the outcome, One-Way ANOVA tests followed by Games-Howell or Tukey, and Kruskal-Wallis followed by Dunn were applied. All groups showed a variation in total volume and regardless of the technique used, the cervical third had greater magnification when compared to the apical one (p <0.05). Regarding the percentage of non-instrumented areas and debris, significant differences were observed for WOG Medium versus WOG Small to WOG Medium (p <0.05). Both techniques, SF and MF, provided volume variation after preparation, with persistence of non-instrumented areas and debris. However, better results occur when there has been greater enlargement of the root canal.
References
Alencar, A. H. G., Figueiredo, J. A. P., & Estrela, C. (2008). Microtomografia computadorizada na avaliação do preparo do canal radicular: análise crítica. Robrac, 17(44), 159-165.
Baratto-Filho, F., Leonardi, D. P., Zielak, J. C., Vanni, J. R., Sayão-Maia, S. M. A., & Sousa-Neto, M. D. (2009). Influence of protaper finishing files and sodium hypochlorite on cleaning and shaping of mandibuldar central incisors - a histological analysis. Journal of Applied Oral Science, 17(3), 229-233.
Bueno, C., Oliveira, D. P., Pelegrine, R. A., Fontana, C. E., Rocha, D., & Bueno, C. (2017). Fracture incidence of WaveOne and Reciproc files during root canal preparation of up to 3 posterior teeth: A prospective clinical study. Journal of Endodontics, 43(5), 705–708. https://doi.org/10.1016/j.joen.2016.12.024
Busquim, S., Cunha, R. S., Freire, L., Gavini, G., Machado, M. E., & Santos, M. (2015). A micro-computed tomography evaluation of long-oval canal preparation using reciprocating or rotary systems. International Endodontic Journal, 48(10), 1001-1006. doi: 10.1111/iej.12398
De-Deus, G., Marins, J., Neves, A., Reis, C., Fidel, S., Versiani, M. A., Alves, H., Lopes, R. T., & Paciornik, S. (2014). Assessing accumulated hard-tissue debris using micro-computed tomography and free software for image processing and analysis. Journal of Endodontics, 40(2), 271-276. https://doi.org/10.1016/j.joen.2013.07.025
De-Deus, G., Belladonna, F. G., Silva, E. J., Marins, J. R., Souza, E. M., Perez, R., Lopes, R. T., Versiani, M. A., Paciornik, S., & Neves, A. (2015). Micro-CT evaluation of non-instrumented canal areas with different enlargements performed by NiTi systems. Brazilian Dental Journal, 26(6), 624-629. https://doi.org/10.1590/0103-6440201300116
De-Deus, G., Belladonna, F. G., Zuolo, A. S., Cavalcante, D. M., Carvalhal, J. C. A., Simões-Carvalho, M., Souza, E. M., Lopes, R. T., & Silva, E. J. N. L. (2019). XP-endo Finisher R instrument optimizes the removal of root filling remnants in oval-shaped canals. International Endodontic Journal, 52(6), 899-907. https://doi.org/10.1111/iej.13077
Espir, C. G., Nascimento, C. A., Guerreiro-Tanomaru, J. M., Bonetti-Filho, I., & Tanomaru-Filho, M. (2018). Radiographic and micro-computed tomography classification of root canal morphology and dentin thickness of mandibular incisors. Journal of Conservative Dentistry: JCD, 21(1), 57-62.
Gergi, R., Arbab-Chirani, R., Osta, N., & Naaman, A. (2014). Micro-computed tomographic evaluation of canal transportation instrumented by different kinematics rotary nickel-titanium instruments. Journal of Endodontics, 40(8), 1223-1227. https://doi.org/10.1016/j.joen.2014.01.039
Gergi, R., Osta, N., Bourbouze, G., Zgheib, C., Arbab-Chirani, R., & Naaman, A. (2015). Effects of three nickel titanium instrument systems on root canal geometry assessed by micro-computed tomography. International Endodontic Journal, 48(2), 162–170. https://doi.org/10.1111/iej.12296
Guillén, R. E., Nabeshima, C. K., Caballero-Flores, H., Cayón, M. R., Mercadé, M., Cai, S., & Machado, M. E. L. (2018). Evaluation of the WaveOne Gold and One Shape New Generation in reducing Enterococcus faecalis from root canal. Brazilian Dental Journal, 29(3), 249-253. https://doi.org/10.1590/0103-6440201801910
Guimarães, L. S., Gomes, C. C., Marceliano-Alves, M. F., Cunha, R. S., Provenzano, J. C., & Siqueira, J. F., Jr (2017). Preparation of Oval-shaped canals with TRUShape and Reciproc systems: A micro-computed tomography study using contralateral premolars. Journal of Endodontics, 43(6), 1018-1022. https://doi.org/10.1016/j.joen.2017.01.028
Hülsmann, M., Rümmelin, C., & Schäfers, F. (1997). Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: a comparative SEM investigation. Journal of Endodontics, 23(5), 301-306. https://doi.org/10.1016/S0099-2399(97)80410-4
Langeland, K., Liao, K., & Pascon, E. A. (1985). Work-saving devices in endodontics: efficacy of sonic and ultrasonic techniques. Journal of Endodontics, 11(11), 499-510. https://doi.org/10.1016/s0099-2399(85)80223-5
Lim, Y. J., Park, S. J., Kim, H. C., & Min, K. S. (2013). Comparison of the centering ability of Wave·One and Reciproc nickel-titanium instruments in simulated curved canals. Restorative Dentistry & Endodontics, 38(1), 21-25. https://doi.org/10.5395/rde.2013.38.1.21
Lorencetti, K. T., Silva-Sousa, Y. T. C., Nascimento, G. E., Messias, D. C. F., Colucci, V., Rached-Junior, F. A., & Silva, S. R. C. (2014). Influence of apical enlargement in cleaning of curved canals using negative pressure system. Brazilian Dental Journal, 25(5), 430-434. https://doi.org/10.1590/0103-6440201302435
Milanezi de Almeida, M., Bernardineli, N., Ordinola-Zapata, R., Villas-Bôas, M. H., Amoroso-Silva, P. A., Brandão, C. G., Guimarães, B. M., Gomes de Moraes, I., & Húngaro-Duarte, M. A. (2013). Micro-computed tomography analysis of the root canal anatomy and prevalence of oval canals in mandibular incisors. Journal of Endodontics, 39(12), 1529-1533. https://doi.org/10.1016/j.joen.2013.08.033
Neves, M. A., Provenzano, J. C., Rôças, I. N., & Siqueira, J. F., Jr (2016). Clinical antibacterial effectiveness of root canal preparation with reciprocating single-instrument or continuously rotating multi-instrument systems. Journal of Endodontics, 42(1), 25-29. https://doi.org/10.1016/j.joen.2015.09.019
Nielsen, R. B., Alyassin, A. M., Peters, D. D., Carnes, D. L., & Lancaster, J. (1995). Microcomputed tomography: an advanced system for detailed endodontic research. Journal of Endodontics, 21(11), 561-568. https://doi.org/10.1016/S0099-2399(06)80986-6
Paqué, F., Laib, A., Gautschi, H., & Zehnder, M. (2009). Hard-tissue debris accumulation analysis by high-resolution computed tomography scans. Journal of Endodontics, 35(7), 1044-1047. doi: 10.1016/j.joen.2009.04.026
Paqué, F., & Peters, O. A. (2011) Micro-computed tomography evaluation of the preparation of long oval root canals in mandibular molars with the self-adjusting file. Journal of Endodontics, 37(4), 517-521. doi: 10.1016/j.joen.2010.12.011
Plotino, G., Grande, N. M., Pecci, R., Bedini, R., Pameijer, C. H., & Somma, F. (2006). Three-dimensional imaging using microcomputed tomography for studying tooth macromorphology. Journal of the American Dental Association (1939), 137(11), 1555-1561.
Plotino, G., Özyürek, T., Grande, N. M., & Gündoğar, M. (2019). Influence of size and taper of basic root canal preparation on root canal cleanliness: a scanning electron microscopy study. International Endodontic Journal, 52(3), 343-351. https://doi.org/10.1111/iej.13002
Robinson, J. P., Lumley, P. J., Claridge, E., Cooper, P. R., Grover, L. M., Williams, R. L., & Walmsley, A. D. (2012). An analytical Micro CT methodology for quantifying inorganic dentine debris following internal tooth preparation. Journal of Dentistry, 40(11), 999-1005. https://doi.org/10.1016/j.jdent.2012.08.007
Schilder H. (1974). Cleaning and shaping the root canal. Dental Clinics of North America, 18(2), 269-296.
Sousa-Neto, M. D., Silva-Sousa, Y. C., Mazzi-Chaves, J. F., Carvalho, K. K. T., Barbosa, A. F. S., Versiani, M. A., Jacobs, R., & Leoni, G. B. (2018). Root canal preparation using micro-computed tomography analysis: a literature review. Brazilian Oral Research, 32(Sup. 1), e66. https://doi.org/10.1590/1807-3107bor-2018.vol32.0066
Tambe, V. H., Nagmode, P. S., Abraham, S., Patait, M., Lahoti, P. V., & Jaju, N. (2014). Comparison of canal transportation and centering ability of rotary protaper, one shape system and wave one system using cone beam computed tomography: An in vitro study. Journal of Conservative Dentistry: JCD, 17(6), 561–565. https://doi.org/10.4103/0972-0707.144605
van der Vyver, P. J., & Vorster, M. (2017). WaveOne® Gold reciprocating instruments: clinical application in the private practice: Part 1. International Dentistry – African Edition, 7(4), 6-19.
van der Vyver, P. J., Paleker, F., Vorster, M., & de Wet, F. A. (2019). Root canal shaping using nickel titanium, m-wire, and gold wire: A micro-computed tomographic comparative study of One Shape, ProTaper Next, and WaveOne Gold instruments in maxillary first molars. Journal of Endodontics, 45(1), 62-67. https://doi.org/10.1016/j.joen.2018.09.013
Velozo, C., Silva, S., Almeida, A., Romeiro, K., Vieira, B., Dantas, H., Sousa, F., & De Albuquerque, D.S. (2020). Shaping ability of XP-endo Shaper and ProTaper Next in long oval-shaped canals: a micro-computed tomography study. International Endodontic Journal, 53(7), 998-1006. https://doi.org/10.1111/iej.13301
Versiani, M. A., Pécora, J. D., & de Sousa-Neto, M. D. (2011). Flat-oval root canal preparation with self-adjusting file instrument: a micro-computed tomography study. Journal of Endodontics, 37(7), 1002-1007. https://doi.org/10.1016/j.joen.2011.03.017
Versiani, M. A., Carvalho, K., Mazzi-Chaves, J. F., & Sousa-Neto, M. D. (2018). Micro-computed tomographic evaluation of the shaping ability of XP-endo Shaper, iRaCe, and EdgeFile systems in long oval-shaped canals. Journal of Endodontics, 44(3), 489-495. https://doi.org/10.1016/j.joen.2017.09.008
Versiani, M. A., Alves, F. R., Andrade-Junior, C. V., Marceliano-Alves, M. F., Provenzano, J. C., Rôças, I. N., Sousa-Neto, M. D., & Siqueira, J. F., Jr (2016). Micro-CT evaluation of the efficacy of hard-tissue removal from the root canal and isthmus area by positive and negative pressure irrigation systems. International Endodontic Journal, 49(11), 1079-1087. https://doi.org/10.1111/iej.12559
Villas-Bôas, M. H., Bernardineli, N., Cavenago, B. C., Marciano, M., Del Carpio-Perochena, A., de Moraes, I. G., Duarte, M. H., Bramante, C. M., & Ordinola-Zapata, R. (2011). Micro-computed tomography study of the internal anatomy of mesial root canals of mandibular molars. Journal of Endodontics, 37(12), 1682-1686. https://doi.org/10.1016/j.joen.2011.08.001
Webber, J. (2015). Shaping canals with confidence: WaveOne GOLD single-file reciprocating system. Roots, 6(3), 34-40.
Wu, M. K., R'oris, A., Barkis, D., & Wesselink, P. R. (2000). Prevalence and extent of long oval canals in the apical third. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics, 89(6), 739-743. https://doi.org/10.1067/moe.2000.106344
Yared, G. (2008). Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. International Endodontic Journal, 41(4), 339-344. doi: 10.1111/j.1365-2591.2007.01351.x
Zuolo, M. L., Zaia, A. A., Belladonna, F. G., Silva, E., Souza, E. M., Versiani, M. A., Lopes, R. T., & De-Deus, G. (2018). Micro-CT assessment of the shaping ability of four root canal instrumentation systems in oval-shaped canals. International Endodontic Journal, 51(5), 564-571. https://doi.org/10.1111/iej.12810
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Prescila Mota de Oliveira Kublitski; Bruna de Souza Romano; Bruno Marques-da-Silva; Flávia Sens Fagundes Tomazinho; Vinícius Rodrigues dos Santos; Wander José da Silva; Luiz Fernando Fariniuk; Lara Dalla Vecchia Beira; Flares Baratto-Filho; Marilisa Carneiro Leão Gabardo
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
1) Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2) Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3) Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.