Evaluation of efficiency and mass transfer in a pulsed packed extraction column

Authors

DOI:

https://doi.org/10.33448/rsd-v9i2.2185

Keywords:

Extraction; Pulsed Packed Extraction Column; Efficiency; Mass transfer coefficient.; Liquid-liquid extraction.

Abstract

Liquid-liquid extraction, or solvent extraction, is a unitary operation designed to separate one or more components from the insertion of a liquid phase that has more affinity with the components of interest. It is a technique used in various industrial process including the food industry, petrochemical and biochemical. Thus, the present work aims to investigate the operational parameters in the performance of a pulsed packed extraction column. The packed used in the extractor ir Raschig’s rings. For this, 30 runs were performed with aqueous acetic acid solution (solute) and 1-butanol solution (solvent) in order to obtain concentration data in the extract and raffinate and with these data to calculate column efficiency and mass transfer coefficient. The Murphree (1925) and Kawase (1990) models were used to calculate the efficiency. The two models chosen for the efficiency calculation presented consistent values. For the calculation of the mass transfer coefficient, six different models were used: Plug Flow Model (PFM), Safari et al. (2012), Kister (1992), Torab-Mostaedi and Safdari (2009b), Diffusion Model and GhaffariTooran et al. (2009). Among these models, two did not present coherent values: Torab-Mostaedi and Safdari (2009b) and GhaffariTooran et al. (2009). With the analysis of the results it was noted that for both efficiency and mass transfer coefficient there was a positive influence. The flow ratio was the one that most influenced column efficiency, with a percentage increase of 33.57%. Finally, an empirical model was developed to correlate column efficiency with operational parameters. The equation showed good agreement with the Murphree equation, presenting an average deviation of 7.35% which is a relatively low deviation. Thus it was possible to verify the usefulness of the packed insertions and pulsation in the extractor as a way to improve the mass transfer.

References

Amani, P., Amani, M. e Hasanvandian, R. (2017). Investigation of hydrodynamics and mass transfer of mercaptan extraction in pulsed and non-pulsed packed columns. Korean Journal Chemical Engineering, 34, 1456-1465.

Asadollahzadeh, M., Haghighi-Asl, A., Safdari, J. e Torab-Mostaedi, M. (2011). Flooding characteristics in pulsed packed extraction columns. Brazilian Journal of Chemical Engineering, 28, 639-648.

Costa, J. C. (2016). Estudo hidrodinâmico de uma coluna de extração pulsada com recheio. Dissertação (Mestrado). Salvador – Bahia. Universidade Federal da Bahia – BA.

Fox, R. W., Pritchard, P. J. e McDonald, A. T. (2011). Introduction to fluid mechanics, John Wiley & Sons, New York.

GhaffariTooran, S., Abolghasemi, H., Bahmanyar, H., Esmaeili, M. e Safari, A. (2009). A new correlation for overall Sherwood number in packed liquid-liquid extraction column. World Academy of Science Engineering Technology, 55.

Góis, L. M. N. (1995) Estudo e desenvolvimento de um extrator de pratos perfurados pulsantes. Tese (Doutorado). Campinas – São Paulo. Universidade Estadual de Campinas – SP.

González, B., Dominguez, A. e Tojo, J. (2004). Dynamic viscosities, densities, and speed of sound and derived properties of the binary systems acetic acid with water, methanol, ethanol, ethyl acetate and methyl acetate at T=(293.15, 298.15 and 303.15) K at atmospheric pressure. Journal of Chemical & Engineering Data, 49, 1590-1596.

Jaradat, M., Attarakih, M. e Bart, H. (2011). Advanced prediction of pulsed (packed and sieve plate) extraction columns performance using population balance modeling. Chemical Engineering Research Design, 89, 2752-2760.

Jie, Y. e Weiyang, F. (2000). Hydrodynamics and mass transfer in a pulsed packed column. Canadian Journal of Chemical Engineering, 78, 1040-1045.

Kawase, Y. (1990). Dispersed-phase holdup and mass transfer in a rotating disc contactor with perforated skirts. Journal of Chemical Technology BioTechnology, 48, 247-260.

Khooshechin, S., Safdari, J., Moosavian, M. A. e Mallah, M. H. (2013). Prediction of pressure drop in liquid-liquid pulsed packed extraction countercurrent columns. International Journal of Heat and Fluid Flow, 44, 684-691.

Kister, H.Z. (1992). Distillation Design. McGraw-Hill, New York.

Locket, M. J. (1986). Distillation tray fundamentals. Cambridge: Cambridge University Press.

Mirzaie, M., Sarrafi, A., Hashemipour, H., Baghaie, A. e Molaeinasab, M. (2017). CFD simulation and experimental investigation of the copper solvent extraction in a pilot plat pulsed packed column in Sarcheshmeh. Heat Mass Transfer, 53, 1995-2008.

Moghadam, E., Bahmanyar, H., H., Heshmatifar, F., Kasaie, M. e Ziaei-Azad, H. (2016). The investigation of mass transfer coefficients in a pulsed regular packed column applying SiO2 nanoparticles. Separation and Purification Tchnology, 176, 15-22.

Murphree, E.V. (1925). Rectifying column calculations – with particular reference to N component mixtures. Ind. Eng. Chem., 17, 747-750.

Potnis, G. V., Bijawat, H. C. e Doraiswamy, L. K. (1959). Pulse application – packed column. Journal of Industries and chemical engineering, 51, 645-650.

Safari, A., Safdari, J., Abolghasemi, H., Forughi, M. e Moghaddam, M. (2012). Axial mixing and mass transfer investigation in a pulsed packed liquid-liquid extraction column using plug flow and axial dispersion models. Chemical Engineering Research and Design, 90, 193-200.

Samani, M. G., Asl, A. H., Safdari, J. e Torab-Mostaedi, M. (2012). Drop size distribution and mean drop size in a pulsed packed extraction column. Chemical Engineering Research and Design, 90, 2148-2154.

Spasojevic, V.D., Djordjevié, B.D., Serbanovic, S.P. e Radovic, I.R. (2014) Densities, refractive indices, viscosities, and spectroscopic study of 1-amino-2-propanol + 1-butanol solutions at (288.15 to 333.15) K. Chemical Engineering Data, 59, 1817-1829.

Teflanab, R., Ghoreishi, S. M., Safdari, J. e Torab-Mostaedi, M. (2015). Axial dispersion model in predictive mass transfer correlation for random pulsed packed column. Chemical Industry & Chemical Engineering Quarterly, 21, 77-83.

Torab-Mostaedi, M. e Safdari, J. (2009). Mass transfer coefficients in a pulsed packed extraction column. Chemical Engineering Process., 48, 1321-1326.

Vallés, C., Pérez, E., Mainar, A.M., Santafé, J. e Dominguez, M. (2006). Excess enthalpy, density, speed of sound, and viscosity for 2-methyltetrahydrofuran + 1-butanol at (283.15, 298.15, and, 313.15) K. Chemical Engineering Data, 51, 1105-1109.

Published

01/01/2020

How to Cite

BERNARDES, A. P. D.; GÓIS, L. M. N. Evaluation of efficiency and mass transfer in a pulsed packed extraction column. Research, Society and Development, [S. l.], v. 9, n. 2, p. e132922185, 2020. DOI: 10.33448/rsd-v9i2.2185. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/2185. Acesso em: 27 dec. 2024.

Issue

Section

Exact and Earth Sciences