Evaluation of the application parameters of the high-frequency generator in the tissue repair process of skin wounds: an experimental study

Authors

DOI:

https://doi.org/10.33448/rsd-v11i7.29613

Keywords:

Electrical Stimulation Therapy; Healing; Ozone.

Abstract

Introduction: The high frequency generator (HF) employs ozone in the treatment of health systems, producing heat, increasing peripheral vasodilation, cellular metabolism and the local technical repair process. However, there is still no protocol for the parameters in the current literature. Objective: To evaluate the tissue repair process in cleaning processes of different parameters of PA intensity and time. Methodology: Prospective, analytical, interventional, multicenter, experimental, controlling and randomized study. Thirty-five Wistar rats were used, divided into seven groups of five animals each, as follows: six experimental groups and one group. 1, were treated once a lesion with a consecutive diameter punch. Macroscopic analysis was performed, through photographic records of the wound area and microscopic analysis through histological slides. Research approved by the Ethics Committee for the Use of Animals of the Universidade do Estado do Pará, protocol n° 39/20. Results: The morphometric results had a significant reduction of the lesion area in the groups treated by 60 mediums with low and medium. In addition, it was found that a high intensity had a negative effect on the technical repair process. Conclusion: The choice of resource parameters is a repair factor for the use of processless AF. The application with low/medium intensity, for 60 seconds, was the most suitable for the tissue repair process, since it accelerated this process.

References

Bocci, V., Zanardi, I., & Travagli, V. (2011). Oxygen/ozone as a medical gas mixture. A critical evaluation of the various methods clarifies positive and negative aspects. Medical gas research, 1(1), 6.

Borges, F. D. S., Scorza, F. A., & Jahara, R. S. (2010). Modalidades terapêuticas nas disfunções estéticas. Phorte, 224-63.

Brasileiro, F. G., Bogliolo patologia. (9a ed.), Guanabara Koogan, 2017

Colégio Brasileiro de Experimentação Animal – COBEA. Disponível em:< http://ses.sp.bvs.br/lis/resource/35979#.Ww651Sin_IU.

Campagnolo, M. I. (2012). Avaliação da cauterização completa da luz tubária com diferentes potências de eletrocoagulação bipolar para esterilização feminina.

Costa, L. A., & Guimarães, M. M. (2019). O Uso da Alta Frequência na Cicatrização de Lesão por Pressão/The Use of High Frequency in Pressure Injury Healing. ID on line. Revista de psicologia, 13(48), 93-100.

De Oliveira, L. M. N. (2011). Utilização do ozônio através do aparelho de alta frequência no tratamento da úlcera por pressão. Revista de Atenção à Saúde, 9(30).

Higa, D. R., Cese, P. C., Falcão, R. M. M., Cese, A. C., Chang, M. R., Borges, F. S., & Madeira-Oliveira, J. T. (2007). Efeito do gerador de alta frequência sobre cultura de Candida tropicalis. Revista de Especialização em Fisioterapia, 1(1), 1-8.

Hochman, B., Nahas, X. F., Filho, R. S. O., Ferreira, L. M. (2005). Desenhos de pesquisa. Acta Cirúrgica Brasileira. 20, 2- 9.

Iordanou, Panagiota et al. Efeito da luz polarizada visível e infravermelha no processo de cicatrização de feridas cutâneas de espessura total: um estudo experimental. Fotomedicina e cirurgia a laser. 27(2), 261-267, 2009.

Korelo, R. I. G., Oliveira, J. J. J. D., Souza, R. S. A., Hullek, R. D. F., & Fernandes, L. C. (2013). High frequency generator as treatment in scar pressure ulcers: pilot study. Fisioterapia em Movimento, 26, 715-724.

Machado, R. S. (2017). Comparação dos efeitos do laser de baixa potência, do gerador de alta frequência e do curativo no tratamento de pacientes com lesão por pressão durante a internação hospitalar: ensaio clínico randomizado.

Martins, A., Silva, J. T. D., Graciola, L., Fréz, A. R., Ruaro, J. A., & Marquetti, M. D. G. K. (2012). Efeito bactericida do gerador de alta frequência na cultura de Staphylococcus aureus. Fisioterapia e Pesquisa, 19, 153-157.

Mathilde, R. N. F, Lydia, C, Steven, B, Ewa, M, Steven, O, Nicole, querida,Pamela Ritchie,Arto Määttä,Iakowos Karakesisoglou,Glyn Nelson,Thomas von Zglinicki,Teresa Dicolandrea,Robert Isfort,Charles Bascom,Stefan Przyborski.

Meireles, G. C. et al. Efectividad de la fotobiomodulación láser a 660 o 780 nanómetros en la reparación de quemaduras de tercer grado en ratas diabéticas. Fotomedicina y cirugía láser, v. 26, núm. 1, pág. 47-54, 2008.

Pchepiorka, R., Moreira, M. S., da Silva Lascane, N. A, Catalani, L. H, Allegrini Jr, S., & de Lima, N. B. (2020). Efeito da ozonioterapia na cicatrização de feridas na mucosa bucal de ratos. Arquivos de Biologia Oral, 119, 104889.

Recio, AC, Felter, CE, Schneider, AC, & McDonald, JW (2012). Estimulação elétrica de alta voltagem para o manejo de úlceras de pressão estágio III e IV em adultos com lesão medular: demonstração de sua utilidade para feridas recalcitrantes abaixo do nível da lesão. O jornal da medicina da medula espinhal , 35 (1), 58-63.

Rodrigues, A. B. F., da Silva, R. A., Hage, R., & Khouri, S. (2019). Estudo comparativo de dois eletrodos associados ao plasma elétrico de alta frequência na redução do crescimento de cepas clínicas de Malassezia spp. Revista Amazônia: Science & Health, 7(3), 2318-1419.

Sá, H. P., Nunes, H. M., do Santo, L. A. E., de Oliveira Júnior, G. C., da Silva, J. M. N., Carvalho, K. C., & dos Santos Alves, W. (2010). Estudo comparativo da ação do laser GaAlInP e do gerador de alta frequência no tratamento de feridas cutâneas em ratos: estudo experimental. ConScientiae saúde, 9(3), 360-366.

Santos, C G M D, Melo, B V D, & Mello, S M B D (2016). Comparação dos efeitos da laserterapia e corrente de alta frequência na cicatrização de feridas abertas.

Schuh, C. M., Alves, K. A., Wollmann, L., Rodrigues, P. R., Araújo, T. O., & Sudbrack, A. C. (2017). Associação da alta frequência, laser de baixa potência e microcorrentes no tratamento da lesão por pressão. Cinergis, 18(2), 99-103.

Sousa, R C D, Maia Filho, A L M, Nicolau, R A, Mendes, L M S, Barros, T L D, & Neves, S M V (2015). Ação do laser AlGaInP e do gerador de alta frequência na cicatrização de feridas cutâneas. Um estudo comparativo. Acta cirurgica brasileira, 30, 791-798.

Tacani, P M, Tacani, R E, Machado, A., Montezello, D., Góes, J., Marx, A G, & Liebano, R E (2018). Gerador de Alta Frequência na Cicatrização da Úlcera de Marjolin após Ressecção de Carcinoma. Avanços no tratamento de feridas, 7 (5), 165-170.

Published

18/05/2022

How to Cite

COSTA, T. S. da .; MARINHO, D. F.; SILVEIRA, T. S. .; SILVA, M. S. O.; NASCIMENTO, Érica da S.; NASCIMENTO, D. C. S. do; LEITE, I. C. M.; MORINI, A. C. Evaluation of the application parameters of the high-frequency generator in the tissue repair process of skin wounds: an experimental study. Research, Society and Development, [S. l.], v. 11, n. 7, p. e13111729613, 2022. DOI: 10.33448/rsd-v11i7.29613. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/29613. Acesso em: 22 nov. 2024.

Issue

Section

Health Sciences