Ionizographic detector for Breast Cancer Diagnosis

Authors

DOI:

https://doi.org/10.33448/rsd-v10i9.17229

Keywords:

Cancer; Nodule; Breast; PET-CT.

Abstract

Every day the number of cancer victims increases. In 2020 alone, 626,030 people were affected in Brazil, according to estimates by the National Cancer Institute (INCA). The only way to reduce these numbers is early diagnosis. In the present study, a invention called Ionizographic Detector is described, which performs Positron Emission Tomography (PET) producing metabolic information in breast nodules. This device enables accurate diagnosis of breast nodules regarding its malignancy. To prove its effectiveness, a comparative evaluation was made between the Ionizographic Detector and the Positron Emission Tomography/Computerized Tomography (PET-CT) for analysis of the metabolic data in breast nodules. The research is being carried out with 20 patients who have histopathologically documented breast cancer. From the results it will be possible to prove the device’s efficacy. It will thus enable an accurate and low-cost malignancy diagnosis option. The Ionizographic Detector can be hybridized with some anatomical imaging technology, such as Ultrasound (US). With this, it is possible to promote greater access to accurate diagnoses, significantly increasing the possibility of early diagnoses, enabling a cure or a better prognosis for the patient.

References

Alvares, B. R., & Michell, M. (2003). O uso da ressonância magnética na investigação do câncer mamário. Radiologia Brasileira, 36(6), 373-378.

Silva, P. A. D., & Riul, S. D. S. (2011). Câncer de mama: fatores de risco e detecção precoce. Revista Brasileira de Enfermagem, 64(6), 1016-1021.

Barra, F. R., Barra, R. R., & Barra Sobrinho, A. (2012). Novos métodos funcionais na avaliação de lesões mamárias. Radiologia Brasileira, 45(6), 340-344.

Bitencourt, A. G. V., Lima, E. N. P., Chojniak, R., Marques, E. F., Souza, J. A. D., Graziano, L., & Osório, C. A. B. D. T. (2014). Correlação entre resultado do PET-CT e achados histológicos e imuno-histoquímicos em carcinomas mamários. Radiologia Brasileira, 47(2), 67-73.

Boylestad, R. (2013). Dispositivos Eletrônicos e Teoria de Circuitos-11a.

Brasil. Ministério da Saúde, Secretaria de Atenção à Saúde, Instituto Nacional de Câncer (2006). Controle do Câncer de Mama: documento de consenso. Rio de Janeiro.

Calas, M. J. G., Koch, H. A., & Dutra, M. V. P. (2007). Ultra-sonografia mamária: avaliação dos critérios ecográficos na diferenciação das lesões mamárias. Radiologia Brasileira, 40(1), 1-7.

Calas, M. J. G., Gutfilen, B., & Pereira, W. C. D. A. (2012). CAD e mamografia: por que usar esta ferramenta? Radiologia Brasileira, 45(1), 46-52.

Camargo, E. E. (2005). Experiência inicial com PET/CT. Radiologia Brasileira, 38(1), 0-0.

Chala, L. F., & Barros, N. D. (2007). Avaliação das mamas com métodos de imagem. Radiologia Brasileira, 40(1), 4-6.

Jales, R. M., Marussi, E. F., Andrade, K. C. D., & Derchain, S. F. M. (2005). Desempenho da ultra-sonografia na detecção das metástases em linfonodos axilares em mulheres com câncer de mama. Revista Brasileira de Ginecologia e Obstetrícia, 27(9), 534-540.

Johnson, D. E., Hilburn, J. L., & Johnson, J. R. (1994). Fundamentos de análise de circuitos elétricos. Livros Tecnicos e Cientificos.

Kasper, D. L. et al. Medicina Interna de Harrison. (2016) (19a ed.), AMGH Editora LTDA.

Machado, A. C. B., Pleitez, V., & Tijero, M. C. (2006). Usando a antimatéria na medicina moderna. Revista Brasileira de Ensino de Física, 28(4), 407-416.

Nascimento, J. H. R. D., Silva, V. D. D., & Maciel, A. C. (2009). Acurácia dos achados ultrassonográficos do câncer de mama: correlação da classificação BI-RADS® e achados histológicos. Radiologia Brasileira, 42(4), 235-240.

Nascimento, F. B. D., Pitta, M. G. D. R., & Rêgo, M. J. B. D. M. (2015). Análise dos principais métodos de diagnóstico de câncer de mama como propulsores no processo inovativo. Arquivos de medicina, 29(6), 153-159.

Nastri, C. O., Martins, W. D. P., & Lenharte, R. D. J. (2011). Ultrassonografia no rastreamento do câncer de mama. Femina, 97-102.

Nilsson, J. W. & Riedel, Susan A. Circuitos Elétricos. (2015) (10a ed.), Person Education do Brasil.

Sabbatini, R. M. E. (1999) Uma Revolução Feita de Imagens. Chek-Up.

Silva, J. M., Marques, M. A., Moraes, E. C., & Melo, H. J. F. Tomografia Por Emissão De Pósitrons/Ressonância Magnética Na Avaliação Do Câncer De Mama.

Souza, A. R. D., Paixão, A. C., Uzêda, D. D., Dias, M. A., Duarte, S., & Amorim, H. S. D. (2011). A placa Arduino: uma opção de baixo custo para experiências de física assistidas pelo PC. Revista Brasileira de Ensino de Física, 33(1), 01-05.

Pereira, A. S., Shitsuka, D. M., Parreira, F. J., & Shitsuka, R. (2018). Metodologia da Pesquisa Científica-Licenciatura.

Pereira, M. R., Santos, A., & Sakae, T. M. (2010). Escore thrombolysis in myocardial infarction para avaliação de risco em síndrome coronariana aguda em hospital particular no Sul do Brasil. Rev Bras Clin Med, 8(4), 311-5.

Villar, V. C. F. L., De Seta, M. H., Andrade, C. L. T. D., Delamarque, E. V., & Azevedo, A. C. P. D. (2015). Evolution of mammographic image quality in the state of Rio de Janeiro. Radiologia brasileira, 48(2), 86-92.

, 48(2), 86-92.

Published

25/07/2021

How to Cite

MATOS, H. G. .; RAMOS, M. A. R.; VIEIRA, L.; PIRES, A. O. . Ionizographic detector for Breast Cancer Diagnosis. Research, Society and Development, [S. l.], v. 10, n. 9, p. e24410917229, 2021. DOI: 10.33448/rsd-v10i9.17229. Disponível em: https://rsdjournal.org/index.php/rsd/article/view/17229. Acesso em: 19 apr. 2024.

Issue

Section

Health Sciences