Corrosion characterization of the experimental alloy Ti-35Nb-7Zr-5Ta by electrochemical techniques
DOI:
https://doi.org/10.33448/rsd-v10i6.15861Keywords:
Ligas de titânio; Biomateriais; Técnicas eletroquímicas; Corrosão; Osseointegração.Abstract
The objective of the present study was to evaluate the corrosion resistance of the experimental alloy Ti-35Nb-7Zr-5Ta, modified by laser beam, in a physiological solution of 0.9% NaCl. This evaluation was carried out by open circuit potential analysis (EOCP), potentiodynamic polarization curves and cyclic polarization curves. The open circuit potential curves show the specimen irradiated by laser beam at 35 Hz presented a more stable and corrosion resistant surface. It was observed in the polarization curves, low current densities in the order of nA /cm2, for all specimen indicating an expected passive behavior for the investigated alloy. The cyclic polarization curves show that for specimen treated with laser, the potential for repassivation (Er) is greater in relation to the potential for corrosion (Ecorr), which indicates greater resistance to corrosion of metal alloys when treated with laser.
References
Chai, Y. W., Kim, H. Y., Hosoda, H., & Miyazaki, S. (2008). Interfacial defects in Ti-Nb shape memory alloys. Acta Materialia, 56(13), 3088–3097. https://doi.org/10.1016/j.actamat.2008.02.045
Chen, J., Rungsiyakull, C., Li, W., Chen, Y., Swain, M., & Li, Q. (2013). Multiscale design of surface morphological gradient for osseointegration. Journal of the Mechanical Behavior of Biomedical Materials, 20, 387–397. https://doi.org/10.1016/j.jmbbm.2012.08.019
De Assis, S. L., Wolynec, S., & Costa, I. (2006). Corrosion characterization of titanium alloys by electrochemical techniques. Electrochimica Acta, 51(8–9), 1815–1819. https://doi.org/10.1016/j.electacta.2005.02.121
Filho, E. D. A., Fraga, A. F., Bini, R. A., & Guastaldi, A. C. (2011). Bioactive coating on titanium implants modified by Nd:YVO 4 laser. Applied Surface Science, 257(10), 4575–4580. https://doi.org/10.1016/j.apsusc.2010.12.056
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009). Ti based biomaterials, the ultimate choice for orthopaedic implants - A review. Progress in Materials Science, 54(3), 397–425. https://doi.org/10.1016/j.pmatsci.2008.06.004
Kuroda, D., Niinomi, M., Morinaga, M., Kato, Y., & Yashiro, T. (1998). Design and mechanical properties of new β type titanium alloys for implant materials. Materials Science and Engineering A, 243(1–2), 244–249. https://doi.org/10.1016/s0921-5093(97)00808-3
Laurindo, C A H; Lepienski, C A; Amorim, F L; Torres, R D; Soares, P. (2018). Mechanical and Tribological Properties of Ca/P-Doped Titanium Dioxide Layer Produced by Plasma Electrolytic Oxidation: Effects of Applied Voltage and Heat Treatment. Tribology Transactions, 61(4), 733–741. https://doi.org/https://doi.org/10.1080/10402004.2017.1404176
Lopes, C. S., Donato, M., & Ramgi, P. (2016). Comparative corrosion behavior of titanium alloys (ti-15mo and ti-6al-4v) for dental implants applications: A review. Corrosão e Protecção de Materiais, 35(2), 05–14. https://doi.org/10.19228/j.cpm.2016.35.04
López, M. F., Gutiérrez, A., & Jiménez, J. A. (2001). Surface characterization of new non-toxic titanium alloys for use as biomaterials. Surface Science, 482–485(PART 1), 300–305. https://doi.org/10.1016/S0039-6028(00)01005-0
Metikoš-Huković, M., Kwokal, A., & Piljac, J. (2003). The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution. Biomaterials, 24(21), 3765–3775. https://doi.org/10.1016/S0142-9612(03)00252-7
Mish, C. E. (2000). Implantes Dentais Contemporâneos. Pancast.
Mohammed, M. T., Khan, Z. A., Geetha, M., & Siddiquee, A. N. (2015). Microstructure, mechanical properties and electrochemical behavior of a novel biomedical titanium alloy subjected to thermo-mechanical processing including aging. Journal of Alloys and Compounds, 634, 272–280. https://doi.org/10.1016/j.jallcom.2015.02.095
Niinomi, M; Kuroda, D; Fukunaga, K I; Morinaga, M; Kato, Y; Yashiro, T; Suzuki, A. (1999). Corrosion wear fracture of new b type biomedical titanium alloys. Materials Science and Engineering A, 263(2), 193–199. https://doi.org/10.1016 / S0921-5093 (98) 01167-8
Paital, S. R., & Dahotre, N. B. (2009). Calcium phosphate coatings for bio-implant applications: Materials, performance factors, and methodologies. Materials Science and Engineering R: Reports, 66(1–3), 1–70. https://doi.org/10.1016/j.mser.2009.05.001
Queiroz, T. P., Souza, F. Á., Guastaldi, A. C., Margonar, R., Garcia-Júnior, I. R., & Hochuli-Vieira, E. (2013). Commercially pure titanium implants with surfaces modified by laser beam with and without chemical deposition of apatite. Biomechanical and topographical analysis in rabbits. Clinical Oral Implants Research, 24(8), 896–903. https://doi.org/10.1111/j.1600-0501.2012.02471.x
Rodrigues, A. V., Oliveira, N. T. C., dos Santos, M. L., & Guastaldi, A. C. (2015). Electrochemical behavior and corrosion resistance of Ti–15Mo alloy in naturally-aerated solutions, containing chloride and fluoride ions. Journal of Materials Science: Materials in Medicine, 26(1), 1–9. https://doi.org/10.1007/s10856-014-5323-0
Rungsiyakull, C., Li, Q., Sun, G., Li, W., & Swain, M. V. (2010). Surface morphology optimization for osseointegration of coated implants. Biomaterials, 31(27), 7196–7204. https://doi.org/10.1016/j.biomaterials.2010.05.077
Santos, L. D. B., Maria, T., Freire, V., Sampaio, N. D. M., & Oliveira, A. S. de. (2007). Aspectos biomecânicos das próteses sobre im- plantes Biomechanics aspects of the implant-supported pros- theses. 6(1), 13–18.
Silva, F. S. d., Bedoya, J., Dosta, S., Cinca, N., Cano, I. G., Guilemany, J. M., & Benedetti, A. V. (2017). Corrosion characteristics of cold gas spray coatings of reinforced aluminum deposited onto carbon steel. Corrosion Science, 114, 57–71. https://doi.org/10.1016/j.corsci.2016.10.019
Trivinho-Strixino, F; Santos, J S; Sikora, M. S. (2017). Electrochemical Synthesis of Nanostructured Materials. Nanostructures, 53–103. https://doi.org/https://doi.org/10.1016/B978-0-323-49782-4.00003-6
Valente, C. B. M. (2017). Estudo do Comportamento Mecânico de uma Liga de Titânio-Tântalo, Ti10Ta, Produzida por LASER Cladding [Universidade Nova de Lisboa]. http://hdl.handle.net/10362/27686
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Ana Elisa Vilicev Italiano; Daniela Vieira Amantéa; Fernando Santos da Silva; Leandro Fernandes; Márcio Luiz dos Santos; Luís Geraldo Vaz
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
1) Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2) Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3) Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.